In many applications, a good Ethernet cable is one that keeps working. But in some installations, such as aboard a passenger train, offshore platform or inside a cleanroom, an Ethernet cable that simply works is no longer enough. It may transmit every packet without error and still be the wrong choice, because it lacks the fire rating required by a rail operator, swells when exposed to drilling mud or sheds microscopic debris into cleanroom air.
This series of blog posts provides an overview of some of the special environments and application areas where regulatory standards or specific physical conditions, beyond electrical performance, determine the type of Ethernet cable needed. These include hazardous areas, rail vehicles, ships, cleanrooms, extreme-heat environments and installations requiring extended cable runs.
Preventing Gas From Traveling Through Ethernet Cable in Hazardous Areas
Ignition at the device is an obvious hazard, but the cable itself presents an equally important if less obvious risk. Voids in a cable’s core can allow flammable gas to migrate along its length, potentially carrying it from a hazardous zone into a safe area or flameproof enclosure.
IEC 60079-14, the installation standard for explosive atmospheres, addresses this risk by specifying cable construction requirements. Cables designed to resist gas migration need compact interstices and fillers, an extruded inner covering and jacket, and fillers that do not absorb moisture. The standard also describes a pressure test in which a short cable sample is sealed into a small enclosure and the rate of pressure loss through the cable is measured. The 2024 edition gives the test results a more prominent role in determining whether an installation requires a standard compression gland or a barrier gland with individual conductor sealing.A purpose-built Ethernet cable illustrates how these construction requirements translate into practice. SAB’s CATLine CAT 6A ExLD cable, for example, specifies longitudinal tightness to prevent gas migration into areas not exposed to explosion hazards, in accordance with IEC 60079-14. It also incorporates a double shield consisting of aluminum foil and tinned copper braid, along with a PUR jacket. The cable’s other ratings address the offshore and outdoor conditions common to many hazardous areas. It is resistant to drilling mud in accordance with IEC 60092-360 and NEK TS 606 offshore standards, offers sunlight and weather resistance, and is specified down to -60°C in static installations. NEK TS 606 evaluates mud resistance by immersing jacket samples in both oil-based and brine-based drilling fluids for 56 days at 70°C. The samples are then assessed for changes in tensile strength, elongation, swelling and weight.
Avoiding Contamination in Cleanrooms and Paint Shops
In most environments, the concern is how surrounding conditions affect the cable. In cleanrooms and paint shops, the question is reversed: What does the cable release into its surroundings? ISO 14644-1 classifies cleanroom air according to particle concentration. Class 1, the strictest classification, permits no more than 10 particles of 0.1 µm or larger per cubic meter of air. A cable flexing inside a cable carrier in such an environment can become a continuous source of abrasion and particle contamination. Cleanroom Ethernet cables address this challenge with TPE jackets designed to minimize particle release. They carry ratings for both Air Cleanliness Class 1 and continuous flexing in cable carriers at a 15 x O.D. bend radius. Examples include SABclean CATLine CAT 5e S, CAT 6A S, CAT 7A S products.
Automotive paint shops face a chemical version of the same problem. Paint-wetting impairment substances (PWIS), including silicones, some fluorinated materials and certain oils and greases, can cause craters and wetting defects in painted surfaces, even at trace concentrations. The industry specification VDMA 24364 sets out how components are tested and classified for PWIS. Cables routed on painting robots should be specified as PWIS-free, and several single-pair Ethernet designs for carriers and robots carry this designation.
Approval Before Installation
For rail, marine, hazardous-area and building work, the specification should identify the applicable standard and hazard level. Procurement records should include the approval certificate or Declaration of Performance. Future posts in this series will cover Ethernet cable considerations for rail, marine, hazardous-area and building work and relevant SAB Ethernet cables for these environments.
For more information, please visit our Ethernet Cable Pages.