Products

Halogen-Free Cables

SABIX® D 320 FRNC

Halogen-Free Data Cables CE

SERIES #: 6320

Shielded flexible low smoke halogen-free (LSHF) SABIX® data cable with colored conductors or pairs and overall tinned copper shield with improved fire performance and extended temperature range - 300V, +90°C

Download PDF
SABIX® D 320 FRNC- SAB Halogen Free Cables (SABIX)

Marking for SABIX® D 320 FRNC 63200614:
SAB BRÖCKSKES D-VIERSEN · SABIX® D 320 FRNC 6 x 0.14 mm² CE

CE
RoHS
PFAS-Free

Application

The SABIX® D 320 FRNC series offers a flexible and robust option for control wiring across diverse applications. Shielded flexible low smoke halogen-free (LSHF) SABIX® data cable with colored conductors or pairs and overall tinned copper shield with improved fire performance and extended temperature range - rated for 300 V, up to 90°C. It is built with a SABIX® jacket for durability and resistance in harsh conditions. With approvals such as CE, RoHS, it meets key international standards. This series also offers halogen-free to perform in demanding environments. By combining technical strength with flexibility, it helps optimize equipment performance and reliability.

Outstanding Features

» Low smoke halogen-free (LSHF)
» No flame propagation
» Good EMC characteristics
» Flame retardant and self-extinguishing
» NF C 32-070 C1
» PFAS free

Construction

Conductor
bare copper strands acc. to VDE 0812
Insulation
SABIX®
Color Code

DIN 47100: see part number

Stranding

in layers resp. pairwise, pairs in layers

Wrappingfoil
Shieldingtinned copper braiding
Jacket MaterialSABIX®
Jacket colorgrayish tan (RAL 7032)

Technical Specifications

Peak operating voltage

26 AWG = max. 350 V
24 - 16 AWG = max. 500 V

Testing voltage

conductor/conductor: 1500 V
conductor/shielding: 1200 V

Minimum bending radius

fixed installation: 5 x O.D.
free movement: 10 x O.D.

Radiation resistance

1 x 107 cJ/kg (100 kGy)

Temperature Range

DIN VDE:
static: -30/+90°C
flexible: -20/+90°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Flame Propagation:
no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 cat. C resp. D

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 + NF C 32-070 C1

Corrosivityin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Smoke Densityacc. to IEC 61034 + VDE 0482-1034
Application in cable tracknot recommended
Approvals
CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part Numbers

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025