Products

Halogen-Free Cables

SABIX® BL 408 FRNC

Halogen-Free Cables for Shipboard

SERIES #: 6408

Flexible low smoke halogen-free (LSHF) SABIX® power cable with improved fire performance for marine applications - 1000V, +90°C

Download PDF
SABIX® BL 408 FRNC- SAB Halogen Free Cables (SABIX)

Marking for SABIX® BL 408 FRNC 64080182:
SAB BRÖCKSKES · D-VIERSEN · SABIX® BL 408 FRNC 1.5 mm² - IEC 60332-3-22 - 0.6/1kV DNV CE

DNV
CE
RoHS
PFAS-Free

Application

The SABIX® BL 408 FRNC series offers a flexible and robust solution for marine power distribution. This low smoke halogen-free (LSHF) SABIX® power cable provides enhanced fire performance and is rated for 0.6/1 kV (1000 V) and up to +90°C. Built with a SABIX® SHF 1 compound jacket (IEC 60092-360), it ensures long-term durability and resistance under demanding shipboard conditions. Certified by DNV, CE, and RoHS, the BL 408 FRNC series fulfills strict international safety standards. Its halogen-free, flame-retardant, and UV-resistant construction minimizes fire risk while ensuring dependable performance in harsh marine environments. As part of the SABIX® BL Power range, it complements the series with reliable power supply cables for electrical components used in shipbuilding and offshore applications.

Outstanding Features

» Low smoke halogen-free (LSHF)
» Asbestos-free
» No flame propagation
» Flame retardant and self-extinguishing
» Flexible
» DNV
» For applications acc. to Hong Kong Convention
» PFAS free

Construction

Conductor
tinned copper strands acc. to IEC 60228, VDE 0295, class 5
Insulation
special SABIX®
Color Code
black (RAL 9005)
Jacket Materialspecial SABIX® SHF 1 compound acc. to IEC 60092-360
Jacket colorblack (RAL 9005)

Technical Specifications

Nominal voltage
Uo/U 0.6/1 kV
Testing voltage

conductor/conductor: 4000 V

Minimum bending radius

fixed installation: 4 x O.D.
free movement: 6 x O.D.

Temperature Range

DIN VDE:
static: -40/+90°C
flexible: -30/+90°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Flame Propagation:
no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A.

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosivityin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Smoke Densityacc. to IEC 61034 + VDE 0482-1034
Flexibilityvery good
Application in cable tracknot recommended
Approvals
DNV, CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Additional Information

Possible on request:

» bare copper strands

» alternative color code and jacket color

Part Numbers

Part notes:

Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025