Products

Halogen-Free Cables

SABIX® A 224 FRNC C1

Halogen-Free Cables for Rail Vehicles

SERIES #: 6224

Low smoke halogen-free (LSHF) SABIX® control cable with black numbered conductors with improved fire performance and temperature range for railway applications acc. to NC C 32-070-C1 - 750V, +90°C

Download PDF
SABIX® A 224 FRNC C1- SAB Halogen Free Cables (SABIX)

Marking for SABIX® A 224 FRNC C1 62241405:
SAB BRÖCKSKES · D-VIERSEN · SABIX® A 224 FRNC C1 14 x 0.5 mm² CE

CE
RoHS
PFAS-Free

Application

With proven quality, the SABIX® A 224 FRNC C1 series provides consistent performance in industrial control systems. This low-smoke, halogen-free (LSHF) SABIX® control cable with black numbered conductors is rated for 750 V and up to 90°C, offering improved fire performance and an extended temperature range. Designed for railway applications in accordance with NC C 32-070-C1, it delivers durability and reliability under demanding conditions. Its halogen-free construction enhances safety and ensures dependable operation in challenging environments. As a flexible multi-conductor control cable, SABIX® A 224 FRNC C1 is specifically engineered for use in automation systems, machine construction, car manufacturing, and railway technologies. With improved fire performance and long service life, it provides safe, efficient, and reliable connectivity across critical industrial and transport applications.

Outstanding Features

» Low smoke halogen-free (LSHF)
» No flame propagation
» Flame retardant and self-extinguishing
» NF C 32-070 C1
» PFAS free

Construction

Conductor
bare copper strands acc. to IEC 60228, VDE 0295, class 5
Insulation
SABIX®
Color Code

black conductors with consecutive numbers acc. to EN 50334 + VDE 0293-334
from 3 conductors: green/yellow ground

Stranding
in layers
Jacket MaterialSABIX®
Jacket colorblack (RAL 9005)

Technical Specifications

Nominal voltage
Uo/U 450/750 V
Testing voltage

conductor/conductor: 3000 V

Minimum bending radius

fixed installation: 4 x O.D.
free movement: 6 x O.D.

Radiation resistance
1 x 107 cJ/kg (100 kGy)
Temperature Range

DIN VDE:
static: -30/+90°C
flexible: -20/+90°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Flame Propagation:
no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 cat. C resp. D

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 + NF C32-070 C1

Smoke Densityacc. to IEC 61034 + VDE 0482-1034
Corrosiveness of conflagration gasesin compliance with IEC 60332-1-2 + VDE 0482-332-1-2 no development of corrosive conflagration gases
Approvals
CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part Numbers

Part notes:

2 conductor cable does not have ground.
Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025