Products

Halogen-Free Cables

SABIX® A 200 FRNC

Halogen-Free Control Cables CE

SERIES #: 6200

Low smoke halogen-free (LSHF) SABIX® control cable with black numbered conductors with improved fire performance and extended temperature range - 500V, +85°C

Download PDF
SABIX® A 200 FRNC- SAB Halogen Free Cables (SABIX)

Marking for SABIX® A 200 FRNC 62001215:
SAB BRÖCKSKES · D-VIERSEN · SABIX® A 200 FRNC 12 x 1.5 mm² CE

CE
RoHS
PFAS-Free

Application

The SABIX® A 200 FRNC series offers a flexible and robust solution for control wiring across diverse applications. This low-smoke, halogen-free (LSHF) SABIX® control cable with black numbered conductors is rated for 500 V and up to 85°C, providing improved fire performance and an extended temperature range. Its SABIX® jacket ensures durability and resistance in harsh operating conditions. Its halogen-free, UV-resistant design ensures reliable performance and long service life in demanding environments. As a flexible multi-conductor power and control cable, SABIX® A 200 FRNC is suitable for use in dry, damp, and wet conditions across all types of electrical equipment. In case of fire, it produces no corrosive gases, making it particularly well-suited for installations where human life and valuable property are at high risk.

Outstanding Features

» Low smoke halogen-free (LSHF)
» No flame propagation
» Flame retardant and self-extinguishing
» Very flexible
» Very good stripping
» PFAS free

Construction

Conductor
bare copper strands acc. to IEC 60228, VDE 0295, class 5
Insulation
SABIX®
Color Code

black conductors with consecutive numbers acc. to EN 50334 + VDE 0293-334
from 3 conductors: green/yellow ground

Stranding
in layers
Jacket MaterialSABIX®
Jacket colorgray (RAL 7000)

Technical Specifications

Nominal voltage
Uo/U 300/500 V
Testing voltage

conductor/conductor: 3000 V

Minimum bending radius

fixed installation: 4 x O.D.
free movement: 6 x O.D.

Temperature Range

DIN VDE:
static: -40/+85°C
flexible: -30/+85°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Flame Propagation:
no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 cat. C resp. D

Fire performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosivityin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Smoke Densityacc. to IEC 61034 + VDE 0482-1034
For flexible applicationsuitable
Flexibilitygood
Application in cable tracknot recommended
Approvals
CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union