Low smoke halogen-free (LSHF) wiring cable with bare copper stranding with improved fire performance and extended temperature range -750V, +90°C
Download PDFMarking for SABIX® A 156 FRNC 61560182:
SAB BRÖCKSKES · D-VIERSEN · SABIX® A 156 FRNC 450/750 V 1.5 mm² CE
The SABIX® A 156 FRNC series combines flexibility with strength, making it a smart choice for automation and control tasks. This low-smoke, halogen-free (LSHF) wiring cable with bare copper stranding is rated for 750 V and up to 90°C, offering improved fire performance and an extended temperature range. Its SABIX® jacket ensures durability and resistance in harsh environments. Certified to EN 45545-2, UN/ECE R118, CE, and RoHS standards, the SABIX® A 156 FRNC series meets key international requirements. Its halogen-free, UV-resistant design provides long service life and dependable performance in demanding industrial applications. As a flexible, flame-retardant single conductor, SABIX® A 156 FRNC is self-extinguishing, non–flame-propagating, and specifically designed for use in areas where human life and valuable property are exposed to a high risk of fire. It supports safe, efficient integration into control panels and automated systems.
» Low smoke halogen-free (LSHF)
» No flame propagation
» Flame retardant and self-extinguishing
» Very good stripping
» Flexible
» Fulfills fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3
» Flame retardant acc. to UN/ECE R118
» PFAS free
| Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 5 |
| Jacket Material | SABIX® |
| Jacket color | 01 = black, 02 = blue, 03 = brown, 04 = gray, 05 = yellow, 06 = green, 07 = violet, 08 = white, 16 = gentian blue, 27 = green/yellow |
| Nominal voltage | Uo/U 450/750 V |
| Testing voltage | 2500 V |
| Minimum bending radius | 7.5 x O.D. 5 x O.D. (for one single bend) |
| Temperature Range | DIN VDE: |
| Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
| Burning Characteristics | Flame Propagation: |
| Corrosivity | in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases |
| Smoke Density | acc. to IEC 61034 + VDE 0482-1034 |
| For flexible application | good |
| Application in track | not recommended |
| Approvals | EN 45545-2, UN/ECE R118, CE, RoHS |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Possible on request:
» tinned copper strands