Shielded continuous flex oil, fuel, and weather resistant, low smoke halogen-free (LSHF) SABIX® cross linked cable with black numbered twisted pairs and overall tinned copper shield for outdoor use in railway applications acc. to EN 45545-2 - 1000V, +90°C
Download PDFMarking for SAB RailLine 560 C TP 65609004:
SAB BRÖCKSKES · D-VIERSEN · SAB RailLine 560 6 x 2 x 0.25mm² C 65609004 CE
The SAB RailLine 560 C TP series offers a flexible and robust solution for demanding railway environments. This shielded, continuous flex, low smoke halogen-free (LSHF) cross-linked SABIX® control cable features black numbered twisted pairs with an overall tinned copper shield, rated for 1000 V and up to +90°C. Its SABIX® X jacket provides outstanding durability and resistance to oil, fuel, weather, and mechanical stress, ensuring dependable long-term use outdoors. Certified to EN 45545-2, CE, and RoHS, the RailLine 560 C TP meets stringent fire safety and quality standards. With oil and fuel resistance per EN 50264-1, it delivers maximum flame protection, non-toxic performance, and enhanced EMC shielding for interference-free operation. Suitable for flexible and outdoor installations in rail cars, machinery, and inter-wagon connections, this paired cable ensures safe, reliable, and efficient connectivity under continuous flex conditions.
Conductor | tinned copper strands, extra fine wires |
Insulation | SABIX® X |
Color Code | black conductors with consecutive numbers acc. to EN 50334 + VDE 0293-334 |
Stranding | in layers resp. pairwise |
Wrapping | foil |
Shielding | tinned copper braiding |
Jacket Material | SABIX® X |
Jacket color | black (RAL 9005) |
Nominal voltage | Uo/U 300/500 V resp. 0.6/1 kV |
Testing voltage | conductor/conductor: 2000 V |
Minimum bending radius | fixed installation: 4 x O.D. |
Torsion angle | ± 15°/1m |
Temperature Range | DIN VDE: |
Halogen-free | acc. to EN 50306-1 + EN 50264-1 Development of HCl is < 0.5% acc. to IEC 60754-1 pH-value is > 4.3 acc. to IEC 60754-2 Conductivity is < 10.0 μS/mm acc. to IEC 60754-2 Fluoric content < 0.1% acc. to IEC 60684-2 |
Burning Characteristics | Flame Propagation: |
Smoke Density | acc. to IEC 61034 + VDE 0482-1034 |
Toxicity | acc. to EN 50305+ VDE 0260-305 |
Oil and fuel resistance | acc. to EN 50264-1 + VDE 0260-264-4 |
Weather resistance | very good |
For flexible application | suitable |
Continuous flexibility | very good |
Approvals | EN 45545-2, UN/ECE R118, CE, RoHS |
Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Part notes:
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025