Low smoke halogen-free (LSHF) SABIX® industrial CAT 7A Ethernet cables with colored star quad stranded conductors or twisted pairs acc. to EN 45545-2 for railway technology - 90V, +70°C
Download PDFMarking for CATLine CAT 7A R 17674621:
SAB BRÖCKSKES · D-VIERSEN · CATLine Cat.7A R 4 x 2 x 26 AWG 1767-4621 CE
The CATLine CAT 7A R series delivers dependable control solutions for modern automation and machinery. Low smoke halogen-free (LSHF) SABIX® industrial CAT 7A Ethernet cables with colored star quad stranded conductors or twisted pairs acc. to EN 45545-2 for railway technology - rated for 90 V, up to 70°C. It is built with a special SABIX® jacket for durability and resistance in harsh conditions. With approvals such as EN 45545-2, UN/ECE R118, CE, RoHS, it meets key international standards. This series also offers halogen-free to perform in demanding environments. Its adaptability allows it to perform reliably in both standard and specialized industrial settings.CATLine 7A R Railway is a halogen-free industrial Ethernet cable that meets railroad fire protection standards. It targets applications such as CAT7A control systems for trains and railway infrastructure. CATLine 7A R Railway compliance with fire protection requirements R15 (EL1A) as per EN 45545-2 for Hazard Levels 1-3. Other features include good EMC characteristics in addition to this cable's excellent fire protection characteristics.
Conductor | bare copper strands, fine wires |
Insulation | PE |
Color Code | white-blue/blue, white-orange/orange, white-green/green, white-brown/brown |
Stranding | twisted to pairs with alu. foil, pairs together |
Shielding | tinned copper braiding |
Jacket Material | special SABIX® |
Jacket color | green (similar RAL 6018) |
Peak operating voltage | max. 90 V |
Testing voltage | conductor/conductor: 750 V |
Minimum bending radius | fixed installation: 5 x O.D. |
Temperature Range | DIN VDE: |
Halogen-free | acc. to EN 50306-1 + EN 50264-1 Development of HCl is < 0.5% acc. to IEC 60754-1 pH-value is > 4.3 acc. to IEC 60754-2 Conductivity is < 10.0 μS/mm acc. to IEC 60754-2 Fluoric content < 0.1% acc. to IEC 60684-2 |
Burning Characteristics | Flame Propagation: |
Smoke Density | acc. to IEC 61034 + VDE 0482-1034 |
Toxicity | acc. to EN 50305 + VDE 0260-305 |
Characteristic impedance | 100Ω± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-9-2 / CAT 7A |
For flexible application | suitable |
Flexibility | good |
Application in cable track | not recommended |
Approvals | EN 45545-2, UN/ECE R118, CE, RoHS |
Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |