CATLine CAT 6A R - 26 AWG/4pr

Part #: 16674621
EN 45545
UN/ECE/R118
CE
RoHS
PFAS-Free

Outstanding Features

» Low smoke halogen-free
» No flame propagation
» Flame retardant and self-extinguishing
» Good against aggressive chemicals
» Fulfills fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3
» Flame retardant acc. to UN/ECE R118
» Suitable for EtherCAT and EtherNET/IP applications
» PFAS free
Questions?

CATLine CAT 6A R

Part #: 16674621

CATLine CAT 6A R - 26 AWG/4pr - low smoke, halogen-free SABIX® industrial CAT 6A Ethernet cables with colored star quad stranded conductors or twisted pairs for acc. to EN 45545-2 for railway technology - 90V, +70°C, CE

Download PDF

Cable Configuration

Dimensions26 AWG (≈18/38)/4pr
mm20.14
AWG26
# of Pairs4
Color Code
white-blue/blue, white-orange/orange, white-green/green, white-brown/brown
JacketGreen SABIX (similar RAL 6018)
Max. cond Ø1.05
Outer Ø ±10% (in)0.268
Outer Ø ±10% (mm)6.80
Voltage90
Cable Weight (≈lbs/mft)37

Construction

Conductor
bare copper strands, fine wires
Insulation
PE
Color Code
white-blue/blue, white-orange/orange, white-green/green, white-brown/brown
Stranding
conductors twisted to pairs, pairs together
Wrappingfoil
Shieldingdouble shield: alu. foil and tinned copper braiding
Jacket Materialspecial SABIX®
Jacket colorgreen (similar RAL 6018)

Technical Specifications

Peak operating voltage
max. 90 V
Testing voltage

conductor/conductor: 750 V
conductor/shielding: 750 V

Minimum bending radius

fixed installation: 5 x O.D.
free movement: 12 x O.D.

Temperature Range

DIN VDE:
static: -40/+70°C
flexible: -30/+70°C

Halogen-free
acc. to EN 50306-1 + EN 50264-1
Development of HCl is < 0.5% acc. to IEC 60754-1
pH-value is > 4.3 acc. to IEC 60754-2
Conductivity is < 10.0 μS/mm acc. to IEC 60754-2
Fluoric content < 0.1% acc. to IEC 60684-2
Burning Characteristics

Flame Propagation:
no flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24 resp. IEC 60332-3-25 + VDE 0482-332-3-25 and EN 50305 + VDE 0260-305 section 9.1.2

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
flame retardant acc. to ISO 6722 (UN/ECE R118)

Smoke Densityacc. to IEC 61034 + VDE 0482-1034
Toxicityacc. to EN 50305 + VDE 0260-305
Characteristic impedance100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-10-2 / CAT 6A
For flexible applicationvery good
Application in tracknot recommended
ApprovalsEN 45545, UN/ECE/R118, CE, RoHS, PFAS-Free
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part notes:

Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025