Low smoke halogen-free (LSHF) SABIX® industrial CAT 6A Ethernet cables with colored star quad stranded conductors or twisted pairs acc. to EN 45545-2 for railway technology - 90V, +70°C
Download PDFMarking for CATLine CAT 6A R 16674621:
SAB BRÖCKSKES · D-VIERSEN · CATLine Cat.6A R 4 x 2 x 26 AWG 1667-4621 CE
Designed with versatility in mind, the CATLine CAT 6A R series delivers reliable performance for railway control and automation systems. These low smoke halogen-free (LSHF) SABIX® CAT 6A Ethernet cables feature colored star quad stranded conductors or twisted pairs, designed in accordance with EN 45545-2 railway standards. Rated for 90 V and up to 70°C, they incorporate a special SABIX® jacket for exceptional durability and resistance in harsh conditions. Certified to EN 45545-2, UN/ECE R118, CE, and RoHS, the CATLine 6A R Railway series meets stringent international fire protection and safety requirements. Complying with fire protection class R15 (EL1A) per DIN EN 45545-2 for Hazard Levels 1–3, these cables provide dependable connectivity and safety in rail applications. Engineered for CAT 6A control systems in trains and railway infrastructure, they combine excellent EMC performance with outstanding fire resistance, ensuring safe and efficient data transmission in critical environments
Conductor | bare copper strands, fine wires |
Insulation | PE |
Color Code | white-blue/blue, white-orange/orange, white-green/green, white-brown/brown |
Stranding | conductors twisted to pairs, pairs together |
Wrapping | foil |
Shielding | double shield: alu. foil and tinned copper braiding |
Jacket Material | special SABIX® |
Jacket color | green (similar RAL 6018) |
Peak operating voltage | max. 90 V |
Testing voltage | conductor/conductor: 750 V |
Minimum bending radius | fixed installation: 5 x O.D. |
Temperature Range | DIN VDE: |
Halogen-free | acc. to EN 50306-1 + EN 50264-1 Development of HCl is < 0.5% acc. to IEC 60754-1 pH-value is > 4.3 acc. to IEC 60754-2 Conductivity is < 10.0 μS/mm acc. to IEC 60754-2 Fluoric content < 0.1% acc. to IEC 60684-2 |
Burning Characteristics | Flame Propagation: |
Smoke Density | acc. to IEC 61034 + VDE 0482-1034 |
Toxicity | acc. to EN 50305 + VDE 0260-305 |
Characteristic impedance | 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-10-2 / CAT 6A |
For flexible application | not suitable |
Flexibility | good |
Application in cable track | not recommended |
Approvals | EN 45545-2, UN/ECE R118, CE, RoHS |
Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |