Continuous flex low smoke halogen-free (LSHF) SABIX® industrial CAT 6A Ethernet cables with colored star quad stranded conductors or twisted pairs acc. to EN 45545-2 for railway technology - 90V, +90°C
Download PDFMarking for CATLine CAT 6A R flex 16694631:
SAB BRÖCKSKES · D-VIERSEN · Cat. 6A R flex 4 x 2 x 26 AWG 1669-4631 CE
Tailored for industrial use, the CATLine CAT 6A R flex series delivers long-lasting performance in railway and automation projects. These continuous flex, low smoke halogen-free (LSHF) SABIX® CAT 6A Ethernet cables feature colored star quad stranded conductors or twisted pairs, designed in compliance with EN 45545-2 railway standards. Rated for 90 V and up to 90°C, they are built with a special SABIX® jacket that ensures exceptional durability under harsh operating conditions. Certified to EN 45545-2, UN/ECE R118, CE, and RoHS, the CATLine 6A R flex series meets stringent international safety requirements. It complies with fire protection requirements R15 (EL1A) and R16 (EL1B) for Hazard Levels 1–3, making it fully suited for railway environments. With excellent oil and fuel resistance, this cable is engineered for CAT 6A control systems in trains and railway infrastructure, combining technical strength with flexibility to ensure safe, efficient, and reliable data transmission.
Conductor | bare copper strands, fine wires |
Insulation | special SABIX® |
Color Code | white-blue/blue, white-orange/orange, white-green/green, white-brown/brown |
Stranding | conductors twisted to pairs, pairs together |
Wrapping | foil |
Shielding | double shield: alu. foil and tinned copper braiding |
Jacket Material | special SABIX® |
Jacket color | green (similar RAL 6018) |
Peak operating voltage | max. 90 V |
Testing voltage | conductor/conductor: 750 V |
Minimum bending radius | fixed installation: 5 x O.D. |
Temperature Range | DIN VDE: |
Halogen-free | acc. to EN 50306-1 + EN 50264-1 Development of HCl is < 0.5% acc. to IEC 60754-1 pH-value is > 4.3 acc. to IEC 60754-2 Conductivity is < 10.0 μS/mm acc. to IEC 60754-2 Fluoric content < 0.1% acc. to IEC 60684-2 |
Burning Characteristics | Flame Propagation: |
Smoke Density | acc. to IEC 61034 + VDE 0482-1034 |
Toxicity | acc. to EN 50305 + VDE 0260-305 |
Characteristic impedance | 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-10-2 / CAT 6A |
Oil and fuel resistance | acc. to EN 50264-1 + VDE 0260-264-1 |
For flexible application | suitable |
Flexibility | good |
Continuous flexibility | very good |
Application in cable track | recommended |
Approvals | EN 45545-2, UN/ECE R118, CE, RoHS |
Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |