Low smoke halogen-free (LSHF) SABIX® industrial CAT 5e Ethernet cables with colored star quad stranded conductors or twisted pairs acc. to EN 45545-2 for railway technology - 90V, +70°C
Download PDFMarking for CATLine CAT 5e R 15674421:
SAB BRÖCKSKES · D-VIERSEN · CATLine Cat.5e R 4 x 2 x 24 AWG 1567-4421 CE
Tailored for industrial use, the CATLine CAT 5e R series ensures long-lasting performance in railway control and automation projects. These low smoke halogen-free (LSHF) SABIX® CAT 5e Ethernet cables feature colored star quad stranded conductors or twisted pairs, designed in accordance with EN 45545-2 for railway technology. Rated for 90 V and up to 70°C, the cables use a special SABIX® jacket for durability and resistance under harsh conditions. Certified to EN 45545-2, UN/ECE R118, CE, and RoHS standards, the CATLine 5e R Railway meets international fire protection and safety requirements. It complies with EN 45545-2 fire protection standard R15 (EL1A) for Hazard Levels 1–3, ensuring reliable performance in rail applications. Engineered for CAT 5e control systems in trains and railway infrastructure, it combines excellent EMC characteristics with outstanding fire protection, offering safe, durable, and efficient data transmission in critical environments.
Conductor | bare copper strands, fine wires |
Insulation | PE |
Color Code | 15672625, 15679002, 15679004: blue, yellow, white, orange |
Stranding | 15672625, 15679002, 15679004: star quad |
Wrapping | foil |
Shielding | double shield: alu. foil and tinned copper braiding |
Jacket Material | special SABIX® |
Jacket color | green (similar RAL 6018) |
Peak operating voltage | max. 90 V |
Testing voltage | conductor/conductor: 750 V |
Minimum bending radius | fixed installation: 5 x O.D. |
Temperature Range | DIN VDE: |
Halogen-free | acc. to EN 50306-1 + EN 50264-1 Development of HCl is < 0.5% acc. to IEC 60754-1 pH-value is > 4.3 acc. to IEC 60754-2 Conductivity is < 10.0 μS/mm acc. to IEC 60754-2 Fluoric content < 0.1% acc. to IEC 60684-2 |
Burning Characteristics | Flame Propagation: |
Smoke Density | acc. to IEC 61034 + VDE 0482-1034 |
Toxicity | acc. to EN 50305 + VDE 0260-305 |
Characteristic impedance | 100Ω± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-2-2 / CAT 5 |
For flexible application | suitable |
Flexibility | good |
Application in cable track | not recommended |
Approvals | EN 45545-2, UN/ECE R118, CE, RoHS |
Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Part notes: