Chemical and solvent resistant FEP connection cable with colored or black numbered conductors with extended temperature range - 600V, +180°C
Download PDFMarking for TA 866 F 38660415:
SAB BRÖCKSKES · D-VIERSEN · TA 866 F AWG 16/4c cURus AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3866-0415 CE
The TA 866 F series offers a flexible and robust solution for demanding connection applications. This FEP connection cable is available with colored or black numbered conductors, providing versatility in wiring configurations. Rated for 600 V and suitable for continuous use up to +180°C, it features a FEP 6YM1 jacket (acc. to VDE 0207-6) that ensures exceptional durability and long service life in harsh environments. Certified to UR, cURus, CE, and RoHS, the TA 866 F series delivers excellent resistance to oils, chemicals, and solvents, along with stability across extreme temperature ranges. Designed for high-performance and precise data or signal transmission, it supports both standard and specialized industrial needs. Typical applications include high-frequency and broadband technology, coaxial and microwave systems, chemical industry operations, furnace construction, brick works, and heating appliances, where both flexibility and chemical resistance are essential.
» Excellent resistance against chemicals and solvents
» Excellent temperature resistance and flexibility at low temperatures
» Excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics
» UL / cUL recognized
| Conductor | tinned copper strands acc. to IEC 60228, VDE 0295, class 5 | 
| Insulation | FEP, 6Y11 acc. to VDE 0207-6 | 
| Color Code | up to 5 conductors: HD 308 (VDE 0293-308): see part number | 
| Stranding | in layers | 
| Jacket Material | FEP, 6YM1 acc. to VDE 0207-6 | 
| Jacket color | black (RAL 9005) | 
| Nominal voltage | Uo/U 300/500 V | 
| Voltage | UR/cUR: 600 V | 
| Testing voltage | conductor/conductor: 2000 V | 
| Minimum bending radius | 7.5 x O.D. | 
| Radiation resistance | 1 x 107 cJ/kg | 
| Temperature Range | UR/cUR: up to +150°C | 
| Burning Characteristics | Fire Performance: | 
| Oil resistance | very good - acc. to UL standard 758, at 80°C after 80 days | 
| Chemical resistance | very good - against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds | 
| For flexible application | good | 
| Application in track | not recommended | 
| Approvals | UR, cURus, CE, RoHS | 
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union | 
Possible on request:
» ETFE or PFA insulated strands
Part notes: