Products

ETFE, FEP, & PFA Cables

BL TA 180 C

Connection Cables for Maritime Use

SERIES #: 3753

Shielded flexible halogen-free FEP connection cable with black numbered conductors and overall tinned copper shield for marine applications - 600V, +180°C

Download PDF
BL TA 180 C- SAB ETFE, FEP and FPA Cables

Marking for BL TA 180 C 37530715:
SAB BRÖCKSKES · D-VIERSEN · BL TA 180 C 7 x 1.5 mm² - IEC 60332-3-22 - 300/500V DNV UR AWM Style 21618 150°C 600V cUR AWM I/II A/B 150°C 600V FT1 FT2 CE

RU
CRU
DNV
CE
RoHS

Application

The BL TA 180 C series is engineered for durability and high performance in extreme marine environments. This shielded, flexible, halogen-free FEP connection cable features black numbered conductors and an overall tinned copper shield, ensuring reliable signal integrity and robust protection. Rated for 600 V and up to +180°C, it is constructed with a rugged FEP jacket that withstands the toughest operating conditions. Certified to UR, cUR, DNV, CE, and RoHS, the BL TA 180 C offers UV, oil, fuel, and chemical resistance, making it ideal for use in engine rooms and other areas exposed to harsh environmental influences. Alongside excellent fire performance, this cable provides high flexibility and ease of installation, ensuring safe, dependable connectivity for marine and offshore applications.

Outstanding Features

» No flame propagation
» Flame retardant and self-extinguishing
» Good EMC characteristics
» Oil and fuel resistant
» Good chemical resistance
» Low and high temperature resistance
» Asbestos-free
» DNV
» UL / cUL recognized

Construction

Conductor
tinned copper strands acc. to IEC 60228, VDE 0295, class 5
Insulation
FEP
Color Code
black conductors with consecutive numbers acc. to EN 50334 + VDE 0293-334
Stranding
in layers
Inner JacketBesilen®
Shieldingtinned copper braiding
Jacket MaterialFEP
Jacket colorblack (RAL 9005)

Technical Specifications

Nominal voltage

Uo/U 300/500 V

Voltage

UR/cUR: 600 V

Testing voltage

conductor/conductor: 2000 V (AC)
conductor/shielding: 2000 V

Minimum bending radius

fixed installation: 5 x O.D.
free movement: 10 x O.D.

Radiation resistance

1 x 107 cJ/kg

Temperature Range

UR/cUR: up to +150°C

DIN VDE:
static: -55/+150°C
flexible: -55/+180°C

Burning Characteristics

Flame Propagation:
no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A.

Fire Performance:
flame retardant and self-extinguishing. acc. to IEC 60332-1-2 + VDE 0482-332-1-2
UL FT1, FT2

Oil and fuel resistancevery good
Chemical resistance
very good - against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds
Approvals
UR, cUR, DNV, CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Additional Information

Possible on request:

» without overall copper shield

» alternative color code and jacket color

Part Numbers

Part notes:

Other dimensions and colors are available on request.