Oil and flame resistant shielded continuous flex halogen-free SABIX insulated and PUR jacketed data cable with colored pairs, 300V, +90°C
Download PDFMarking for SABdynamic 900 Data C TP 9010402:
SAB BRÖCKSKES D-VIERSEN · SABdynamic 900 Data C TP 4x2x0.25mm² cURus AWM Style 20233 AWM I/II A/B 80°C 300V FT1 FT2 0901-0402 CE
Tailored for industrial use, the SABdynamic 900 Data C TP series ensures long-lasting performance in control wiring projects. Oil and flame resistant shielded continuous flex halogen-free SABIX insulated and PUR jacketed data cable with colored pairs, rated for 300 V, up to 90°C. It is built with a PUR with matte surface jacket for durability and resistance in harsh conditions. With approvals such as cURus, CE, RoHS, it meets key international standards. This series also offers halogen-free, uv resistance, oil-resistant, chemical resistance to perform in demanding environments. It ensures lasting durability and supports smooth integration into control panels and automated systems.
| Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 6 | 
| Insulation | SABIX® | 
| Color Code | DIN 47100: see part number | 
| Stranding | specially adjusted layering with non-woven tape over each layer | 
| Shielding | tinned copper braiding | 
| Jacket Material | PUR with matte surface | 
| Jacket color | black (RAL 9005) | 
| Peak operating voltage | max. 350 V | 
| Voltage | cURus: 300 V | 
| Testing voltage | conductor/conductor: 2000 V | 
| Minimum bending radius | fixed installation: 3 x O.D. | 
| Temperature Range | cURus: up to +80°C | 
| Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 | 
| Burning Characteristics | Fire Performance: | 
| Oil resistance | very good - TMPU acc. to IEC 50363-10-2 + VDE 0207-363-10-2 | 
| Chemical resistance | good - against acids, akalines, solvents, hydraulic liquids, etc. | 
| Sunlight resistance | acc. to HD 605 | 
| Ozone resistance | acc. to DIN EN 50396 | 
| Salt water resistance | acc. to UL 1309 | 
| For continuous flexing | very good | 
| Application in track | recommended | 
| Approvals | cURus, CE, RoHS | 
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union | 