Products

Compensation and Extension Cables

A 6-022 L

Shielded Besilen insulated compensating and extension cables

SERIES #: 0428

Round compensation or extension cable with Besilen® (silicone) insulation, 2 stranded conductors together and alu foil shielding - 0.22 mm², +180°C

Download PDF
A 6 L- SAB Compensation and Extension Cables
RoHS
PFAS-Free

Application

Designed with versatility in mind, the A 6-022 L series supports efficient operation in machinery and panels. This round compensation or extension cable features Besilen® (silicone) insulation with two stranded conductors and aluminum foil shielding, rated for 0.22 mm², up to 180°C. It is built with a Besilen® EM9 jacket acc. to EN 50363-2-1 + VDE 0207-363-2-1, providing strong resistance to heat, mechanical stress, and harsh environments. The cable’s halogen-free design ensures low smoke emission and enhanced safety in case of fire. The A 6-022 L series includes aluminum foil shielding with a PETP foil wrapping and a bare copper earth wire (0.5 mm²), offering effective EMC protection and signal integrity. Available as both a compensating and extension cable, it supports multiple thermocouple types including Type K, Type J, and Type T. This combination of thermal performance, shielding, and flexibility makes it highly reliable for demanding industrial applications.

Outstanding Features

» Flame retardant and self-extinguishing
» with alu. foil shield
» PFAS free

Construction

Insulation
Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1
Stranding
2 conductors together
WrappingPETP foil, bare copper ground wire 0.5 mm
Jacket MaterialBesilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1
Shaperound
Conductor constructionstrand

Technical Specifications

Minimum bending radius
7.5 x O.D.
Radiation resistance
2 x 107 cJ/kg
Insulation resistance> 1M Ω x km
Temperature Range

DIN VDE:
static: -40/+180°C
flexible: -25/+180°C
short-term use: +250°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosivityin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Approvals
RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part Numbers

Part notes:

C = compensating cables · X = extension cables
DIN 43710 / 43714 (not valid for type B*): We continue to manufacture compensating and extension cables with color code acc. to DIN 43714 and the basic values of DIN 43710.
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100°C resp. 200°C.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025