Products

Compensation and Extension Cables

A 4 L

Fiber-glass insulated compensating and extension cables

SERIES #: 0415

Oval cable with fiber-glass insulation, 2 stranded parallel conductors, SABtex braiding and tinned steel wire armor - 1.5 mm², +200°C

Download PDF
A 4 L- SAB Compensation and Extension Cables
RoHS
PFAS-Free

Application

Tailored for industrial use, the A 4 L series ensures long-lasting performance in control wiring projects. Designed as an oval cable with fiber-glass insulation, it features two stranded parallel conductors, SABtex braiding, and a tinned steel wire armor for superior mechanical strength and protection. With a conductor size of 1.5 mm² and a high-temperature rating of up to 200°C, this series is built to withstand demanding operating environments. The A 4 L series is halogen-free and engineered for applications where both safety and durability are essential. Its armored design offers resistance to harsh mechanical stress, while the SABtex braiding enhances flexibility and abrasion resistance. With a minimum bending radius of 12 x O.D., low smoke emission, and a compact outer dimension of approx. 5.4 x 7.6 mm, it ensures reliable handling and installation in restricted spaces. Available as both a compensating cable and thermocouple extension cable, the A 4 L provides dependable thermal measurement and control in high-temperature environments. By combining rugged construction with precision performance, it supports safe and efficient operation across a wide range of industrial applications.

Outstanding Features

» Flame retardant and self-extinguishing
» withSABtex braiding
» PFAS free

Construction

Insulation
fiber-glass
Stranding
2 parallel conductors
BraidingSABtex with tracer
Armoringtinned steel wire armoring with tracer
Shapeoval
Conductor constructionstrand

Technical Specifications

Minimum bending radius
12 x O.D.
Temperature Range

DIN VDE:
static: -50/+200°C
flexible: -50/+200°C
short-term use: +300°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Flame Propagation:
no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 Cat. C resp. D

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosivityin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Smoke Densitylow (low smoke emission)
Approvals
RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part Numbers

Part notes:

C = compensating cables · X = extension cables
DIN 43710 / 43714 (not valid for type B*): We continue to manufacture compensating and extension cables with color code acc. to DIN 43714 and the basic values of DIN 43710.
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100°C resp. 200°C.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025