Products

Compensation and Extension Cables

A 3 Ln

Besilen Insulated Compensating and Extension Cables

SERIES #: 0413

Round compensation or extension cable with Besilen® (silicone) insulation and 2 stranded parallel conductors - 1.5 mm², +180°C

Download PDF
A 3 Ln- SAB Compensation and Extension Cables
RoHS
PFAS-Free

Application

Tailored for industrial use, the A 3 Ln series ensures long-lasting performance in control wiring projects. This round compensation or extension cable features Besilen® (silicone) insulation with 2 stranded parallel conductors, rated for 1.5 mm², up to 180°C. It is built with a Besilen® EM9 jacket acc. to EN 50363-2-1 + VDE 0207-363-2-1, providing durability and resistance under harsh conditions. The cable is halogen-free, RoHS compliant, and designed to perform reliably in demanding environments. The A 3 Ln series is available as thermocouple cable type Fe-CuNi, offering a minimum bending radius of 10 × O.D. and compliance with IEC 60754-2 / EN 50267-2-2 / VDE 0482 part 267-2-2, ensuring no development of corrosive conflagration gases. This makes it a safe, dependable option for high-temperature and industrial control applications.

Outstanding Features

» Flame retardant and self-extinguishing
» PFAS free

Construction

Insulation
Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1
Stranding
2 parallel conductors
Jacket MaterialBesilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1
Shapeoval
Conductor constructionstrand

Technical Specifications

Minimum bending radius
10 x O.D.
Radiation resistance
2 x 107 cJ/kg
Insulation resistance> 1M Ω x km
Temperature Range

DIN VDE:
static: -40/+180°C
flexible: -25/+180°C
short-term use: +250°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosivityin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
For flexible applicationgood
Application in tracknot recommended
Approvals
RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Additional Information

Possible on request:

» cross-sections: 1.0 mm², 0.75 mm², 0.5 mm² and 0.22 mm²

Part Numbers

Part notes:

C = compensating cables · X = extension cables
DIN 43710 / 43714 (not valid for type B*): We continue to manufacture compensating and extension cables with color code acc. to DIN 43714 and the basic values of DIN 43710.
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100°C resp. 200°C.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025