Round FEP cable with FEP insulation, 2 stranded conductors together and tinned copper braiding - 1.5 mm², +180°C

Download PDF
A 19 L- SAB Compensation and Extension Cables
RoHS

Application

Tailored for industrial use, the A 19 L series ensures long-lasting performance in control wiring projects. This round FEP thermocouple cable is designed with FEP insulation, two stranded conductors laid together, and an overall tinned copper braiding for reliable shielding and mechanical protection. With a conductor cross-section of 1.5 mm² and temperature resistance up to 180°C, the A 19 L is built to deliver consistent performance even in high-stress environments. The A 19 L series is constructed with a robust FEP jacket that resists chemicals, oils, and solvents, while maintaining flexibility under heat and mechanical stress. Its shielding with tinned copper braiding provides excellent EMC protection, ensuring accurate and stable signal transmission. In addition, it is halogen-free and meets RoHS compliance, supporting higher fire safety standards and environmental responsibility. The cable has been tested to IEC 60332 + EN 60332 Cat. C/D standards, ensuring no flame propagation, making it a dependable solution where fire safety is critical. This series is available as both a compensating cable and a thermocouple extension cable, suitable for various thermocouple types including Type K, J, T, N, R/S, and others. By combining robust shielding, heat resistance, and installation flexibility, the A 19 L series is the right choice for engineers seeking accurate data transmission, long service life, and reliable performance in industries such as process automation, power generation, furnace and kiln construction, and test bench systems.

Outstanding Features

» Very good against fats, oils, salts, and acids
» Flame retardant and self-extinguishing

Construction

Insulation
FEP
Stranding
2 conductors together
Shieldingtinned copper braiding
Jacket MaterialFEP
Shaperound
Conductor constructionstrand

Technical Specifications

Minimum bending radius
12 x O.D.
Radiation resistance
1 x 107 cJ/kg
Insulation resistance> 1M Ω x km
Temperature Range

DIN VDE:
static: -90/+180°C
flexible: -55/+180°C

Burning Characteristics

Flame Propagation:
no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 Cat. C resp. D

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Chemical resistance
very good - against fats, oils, salts and acids
Approvals
RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part Numbers

Part notes:

C = compensating cables · X = extension cables
DIN 43710 / 43714 (not valid for type B*): We continue to manufacture compensating and extension cables with color code acc. to DIN 43714 and the basic values of DIN 43710.
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100°C resp. 200°C.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025