Products

Compensation and Extension Cables

A 15-050 L

Besilen Insulated Compensating and Extension Cables

SERIES #: 0426

Round compensation or extension cable with Besilen® (silicone) insulation and 2 stranded conductors together - 0.75 mm², +180°C

Download PDF
A 15 L- SAB Compensation and Extension Cables
RoHS
PFAS-Free

Application

The A 15-050 L series delivers dependable control solutions for modern automation and machinery. This round compensation or extension cable features Besilen® (silicone) insulation with 2 stranded conductors, rated for 0.50 mm², up to 180°C. It is constructed with a Besilen® EM9 jacket acc. to EN 50363-2-1 + VDE 0207-363-2-1, providing durability and resistance under harsh operating conditions. With RoHS approval, the series meets key international standards and is also halogen-free, ensuring safety in demanding environments. The A 15-050 L series can be supplied as both thermocable and compensating cable. A common choice is Thermocable type K (NiCr-Ni), though other thermocouple types are available upon request. Free of pollutants in accordance with the EU RoHS directive, this cable provides reliable long-term performance for continuous operation at temperatures up to +180°C.

Outstanding Features

» Flame retardant and self-extinguishing
» PFAS free

Construction

Insulation
Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1
Stranding
2 conductors together
Jacket MaterialBesilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1
Shaperound
Conductor constructionstrand

Technical Specifications

Minimum bending radius
7.5 x O.D.
Radiation resistance
2 x 107 cJ/kg
Insulation resistance> 1M Ω x km
Temperature Range

DIN VDE:
static: -40/+70°C
flexible: -25/+70°C
short-term use: +250°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosivityin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Approvals
RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part Numbers

Part notes:

C = compensating cables · X = extension cables
DIN 43710 / 43714 (not valid for type B*): We continue to manufacture compensating and extension cables with color code acc. to DIN 43714 and the basic values of DIN 43710.
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100°C resp. 200°C.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025