Halogen-free SABIX® Interbus-Loop cable with colored conductors - 300V, +85°C

Download PDF
SABIX® IBL 600- SAB Bus Cables

Marking for SABIX IBL 600 56002853:
SAB BRÖCKSKES · D-VIERSEN · SABIX IBL 600 (Logo INTERBUS) Certified No. 204 2 x 1.5 mm² CE

CE
RoHS
PFAS-Free

Application

Engineered for durability, the SABIX® IBL 600 series is designed to excel in demanding control environments. This halogen-free Interbus-Loop cable with colored conductors is rated for 300 V and up to 85 °C. Its SABIX® jacket provides durability and strong resistance in harsh conditions. Its halogen-free, UV- and oil-resistant construction ensures safe, long-lasting performance in challenging applications. The two-conductor version is designed for data transmission and sensor supply, featuring a characteristic impedance of 75 ± 15% at 0.25–10 MHz. The three-conductor version is intended for actuator supply. Both variants are also suitable for use with Interbus-Loop-2, providing engineers with flexibility and reliability in modern automation systems.

Outstanding Features

» Halogen-free
» Very good oil resistance
» Good weather resistance
» Suitable for Interbus-Loop 2
» PFAS free

Construction

Conductor
bare copper strands acc. to IEC 60228, VDE 0295, class 5
Insulation
SABIX®
Color Code

HD 308 (VDE 0293-308): see part number
from 3 conductors: green/yellow ground

Stranding
in layers
Jacket MaterialSABIX®
Jacket colormay green (RAL 6017)

Technical Specifications

Peak operating voltage
max. 350 V
Testing voltage

conductor/conductor: 1500 V

Minimum bending radius
15 x O.D.
Radiation resistance
5 x 106 cJ/kg
Temperature Range

DIN VDE:
static: -50/+90°C
flexible: -40/+90°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Corrosiveness of conflagration gasesin compliance with IEC 60754-2 + VDE 0482- 754-2 - no development of corrosive conflagration gases
Characteristic impedanceat 0.25 - 10 MHz: for two conductor cables 75 Ω ± 15Ω
Oil resistance
very good - acc. to EN 50363-4-1
Weather resistancegood
For flexible applicationvery good
Application in tracknot recommended
Approvals
CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union