Continuous flex hybrid halogen-free PUR Interbus-S installation remote bus cable with colored 18/3 power conductors and twisted pairs suitable for cable tracks - 300V, +80°C
Download PDFMarking for S IBS 618 Hybrid 6186251:
SAB BRÖCKSKES · D-VIERSEN · 06186251 3 x 2 x 0.25 mm² + 3 x 1.00 mm² S IBS 618 24 AWG/3pr + 18 AWG/3c UR AWM Style 20235 80°C CE
The S IBS 618 Hybrid series combines flexibility with strength, making it a smart choice for automation and control tasks. This continuous flex, halogen-free PUR Interbus-S installation remote bus cable features colored 18/3 power conductors and twisted pairs, rated for 300 V and up to 80°C. Its rough-surface PUR jacket provides excellent durability and resistance in harsh operating environments. Certified to UR AWM 20235, CE, and RoHS standards, the S IBS 618 Hybrid series meets key international requirements. Its halogen-free, UV- and oil-resistant construction ensures long service life in demanding conditions. Specially developed for dynamic use in cable tracks, this UL-approved Interbus-S cable complies with DIN VDE 0472 Part 815 and IEC 60754-1 halogen-free standards. It is widely applied in transport and storage technology as well as production engineering, ensuring reliable communication between automation systems and field devices.
Conductor | 24 AWG/3pr: bare copper strands acc. to VDE 0812 |
Insulation | 24 AWG: PE, 2YI1 |
Color Code | 24 AWG pairs: DIN 47100: see part number |
Stranding | twisted to pairs (≤ 24 AWG) pairs & conductors together |
Wrapping | non-woven tape |
Shielding | tinned copper braiding |
Jacket Material | PUR with rough surface |
Jacket color | red lilac (RAL 4001) |
Peak operating voltage | max. 350 V |
Voltage | UR: 300 V |
Testing voltage | conductor/conductor: 2000 V |
Minimum bending radius | 7.5 x O.D. |
Radiation resistance | 5 x 107 cJ/kg |
Temperature Range | UR: up to +80°C |
Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
Burning Characteristics | Fire Performance: |
Characteristic impedance | at 0.064 MHz: 120Ω ± 20Ω; at > 1 MHz: 100Ω ± 15Ω |
Oil resistance | very good - acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Weather resistance | very good |
Direct burial | suitable |
Flexibility | very good |
Continuous flexibility | very good |
Application in cable track | recommended |
Bending characteristics | # of bendings acc. to VDE 0472-603 test method H: min. 1,000,000 single bendings |
Approvals | UR AWM 20235- 80C, CE, RoHS |
Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Applications include
» Interbus-S remote bus cables 3 x 2 x 0.22 mm² or 3 x 2 x 0.25 mm² are used for the sensor/actuator level of industrial communication
Part notes:
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025