
Continuous flex hybrid halogen-free PUR Interbus-S installation remote bus cable with 18/3 power conductors and colored twisted pairs suitable for cable tracks - 300V, +70°C
Download PDFMarking for S IBS 616 Hybrid 6166251:
SAB BRÖCKSKES · D-VIERSEN · S IBS 616 3 x 2 x 0.25 mm² + 3 x 1.00 mm² CE
The S IBS 616 Hybrid series stands out with its adaptability and rugged design, making it ideal for demanding industrial conditions. This continuous flex, halogen-free PUR Interbus-S installation remote bus cable features 18/3 power conductors and colored twisted pairs, rated for 300 V and up to 70°C. Its rough-surface PUR TMPU jacket (EN 50363-10-2) provides durability and resistance under harsh operating conditions. Its halogen-free, UV-, and oil-resistant construction ensures reliable performance and long service life in challenging environments. Engineered for dynamic use in cable tracks, this PUR Interbus-S cable offers high flexibility and resilience. With a peak operating voltage of up to 350 V, it supports safe, efficient communication between automation systems and decentralized field devices.
| Conductor | 24 AWG/3pr: bare copper strands acc. to VDE 0812 |
| Insulation | PE, 2YI1 acc. to EN 50290-2-23 + VDE 0819-103 |
| Color Code | 24 AWG pairs: DIN 47100: see part number |
| Stranding | twisted to pairs (≤ 24 AWG) |
| Wrapping | non-woven tape |
| Shielding | tinned copper braiding |
| Jacket Material | PUR, TMPU acc. to EN 50363-10-2 with rough surface |
| Jacket color | red lilac (RAL 4001) |
| Peak operating voltage | max. 350 V |
| Testing voltage | conductor/conductor: 1500 V |
| Minimum bending radius | 7.5 x O.D |
| Radiation resistance | 5 x 107 cJ/kg |
| Temperature Range | DIN VDE: |
| Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
| Characteristic impedance | at 0.064 MHz: 120Ω ± 20Ω; at > 1 MHz: 100Ω ± 15Ω |
| Oil resistance | very good - acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
| Weather resistance | very good |
| Direct burial | not suitable |
| For flexible application | very good |
| For continuous flexing | very good |
| Application in track | recommended |
| Bending characteristics | # of bendings acc. to VDE 0472-603 test method H: min. 1,000,000 single bendings |
| Approvals | CE, RoHS |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Applications include:
» Interbus-S remote bus cables 3 x 2 x 0.22 mm² or 3 x 2 x 0.25 mm² are used for the sensor/actuator level of industrial communication
Part notes:
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025