

Continuous flex halogen-free PUR Interbus-S remote bus cable with colored twisted pairs suitable for cable tracks - 300V, +70°C
Download PDFMarking for S IBS 616 6163251:
SAB BRÖCKSKES · D-VIERSEN · S IBS 616 3 x 2 x 0.25 mm² CE
With proven quality, the S IBS 616 series ensures reliable performance in industrial control systems. This continuous flex, halogen-free PUR Interbus-S remote bus cable with colored twisted pairs is designed for use in cable tracks. Rated for 300 V and up to 70°C, it features a rough-surface PUR TMPU jacket (EN 50363-10-2) that provides durability and resistance in harsh operating conditions. Its halogen-free, UV- and oil-resistant construction ensures long service life in demanding environments. Engineered for flexibility and resilience, this PUR Interbus-S cable is highly resistant and ideal for dynamic applications in cable tracks. With a peak operating voltage of up to 350 V, it supports efficient, safe, and dependable communication between automation systems and decentralized field devices.
| Conductor | bare copper strands acc. to VDE 0812 | 
| Insulation | PE, 2YI1 acc. to EN 50290-2-23 + VDE 0819-103 | 
| Color Code | DIN 47100: see part number | 
| Stranding | twisted to pairs | 
| Wrapping | non-woven tape | 
| Shielding | tinned copper braiding | 
| Jacket Material | PUR, TMPU acc. to EN 50363-10-2 with rough surface | 
| Jacket color | red lilac (RAL 4001) | 
| Peak operating voltage | max. 350 V | 
| Testing voltage | conductor/conductor: 1000 V | 
| Minimum bending radius | 7.5 x O.D. | 
| Radiation resistance | 5 x 107 cJ/kg | 
| Temperature Range | DIN VDE:  | 
| Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 | 
| Characteristic impedance | at 0.064 MHz: 120Ω ± 20Ω; >1 MHz: 100Ω ± 15Ω | 
| Oil resistance | very good - acc. to EN 50363-10-2 + VDE 0207-363-10-2 | 
| Weather resistance | medium | 
| Direct burial | not suitable | 
| For flexible application | very good | 
| For continuous flexing | very good | 
| Application in track | recommended | 
| Bending characteristics | # of bendings acc. to VDE 0472-603 test method H: min. 1,000,000 single bendings | 
| Approvals | CE, RoHS | 
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union | 
Applications include:
» Interbus-S remote bus cables 3 x 2 x 0.22 mm2 or 3 x 2 x 0.25 mm2 are used for the sensor/actuator level of industrial communication
Part notes:
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025