VFD Combo XLPE-HL - 12 AWG/4c + 18 AWG/1pr - double shielded TC-ER-HL rated, VFD cable for hazardous locations with black numbered conductors, XLPE insulation and shielded pair for variable frequency drives - 1000 V, +105°C, UL Listed, CSA Approved, Class 1 Div 1
Download PDF| Dimensions | 12 AWG/4c + 18 AWG/1pr |
| mm2 | 4 + 1.0 |
| AWG | 12 |
| # of Conductors with ground | 4 |
| # of Pairs | 1 |
| Color Code | Blackish gray numbered conductors including a green/yellow ground, pairs are black numbered #5/#6, |
| Jacket | Black special sunlight and oil resistant copolymer (RAL 9005) |
| Power Conductors | 12 AWG/4c |
| Single Pairs individually shielded | 18 AWG/1pr |
| Outer Ø ±10% (in) | 0.654 |
| Outer Ø ±10% (mm) | 16.60 |
| Voltage | 1000 |
| Cable Weight (≈lbs/mft) | 231 |
| Conductor | tinned copper strands, class K |
| Insulation | special formulated crosslinked PE |
| Color Code | blackish gray conductors with consecutive numbers and green/yellow ground |
| Stranding | in layers |
| Shielding (pair) | alu. foil and drain wire (drain wire same size as pair) |
| Shielding (overall) | double shield: AMA foil and tinned copper braiding |
| Jacket Material | special sunlight and oil resistant copolymer |
| Jacket color | black (RAL 9005) |
| Shape | round |
| Voltage | UL/cUL: 600 V |
| Testing voltage | 3000 V |
| Minimum bending radius | 12 x O.D. |
| Temperature Range | UL/cUL/CSA: up to +90°C static: -40/105°C |
| Burning Characteristics | Fire Performance: UL/CSA FT 4 |
| Oil resistance | UL Oil Res I |
| Sunlight resistance | yes |
| Exposed runs | yes |
| Cold bend test | -40°C |
| Direct burial | suitable |
| For flexible application | very good |
| Application in track | not recommended |
| Machinery area | yes |
| Approvals | UL TC-ER, UL WTTC, c(UL)us, CSA AWM, NFPA 79, CE, RoHS, PFAS-Free |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |