TR 600 S gray - 16 AWG/7c - UV and oil-resistant, flexible gray PVC tray cable with black numbered conductors, type TC-ER, MTW, WTTC, and CSA approved- 600V, +105°C, UL listed, CSA approved
Download PDF| 1 - 39 feet | $1.68/ft |
| 40+ feet | $1.52/ft |
| Dimensions | 16 AWG/7c |
| mm2 | 1.5 |
| AWG | 16 |
| # of Conductors with ground | 7 |
| Color Code | black numbered conductors including a green/yellow ground |
| Jacket | Gray special oil resistant pressure extruded PVC (RAL 7000) |
| Outer Ø (in) | 0.412 |
| Outer Ø (mm) | 10.50 |
| Voltage | 600 |
| Cable Weight (≈lbs/mft) | 126 |
| Conductor | bare copper strands, class K (30 AWG multiple strands) |
| Insulation | special formulated PVC/Nylon |
| Color Code | black conductors with consecutive numbers |
| Stranding | in layers |
| Jacket Material | special oil resistant pressure extruded PVC |
| Jacket color | gray (RAL 7000) |
| Voltage | UL/UR AWM: 600 V |
| Testing voltage | 2500 V |
| Minimum bending radius | fixed installation: 4 x O.D. |
| Temperature Range | UL/CSA: up to +90°C |
| Burning Characteristics | Fire Performance: |
| Oil resistance | UL Oil Res I & II |
| Sunlight resistance | yes |
| Exposed runs | yes |
| Cold bend test | -40°C |
| Direct burial | suitable |
| For flexible application | very good |
| Application in track | not recommended |
| Machinery area | yes |
| Approvals | UL TC-ER, UL MTW, UL WTTC, UR AWM, CSA CIC TC, CSA CIC, CSA AWM, NFPA 79, CE, RoHS, PFAS-Free |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Part notes:
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025