DR 717 P Highflex - 12 AWG/4c - polyurethane (PUR) reeling cable with colored conductors with inner jacket and support screen with extremely high winding and unwinding strength - 500V, +90°C, CE
Download PDF| Dimensions | 12 AWG (≈52/28)/4c |
| mm2 | 4 |
| AWG | 12 |
| # of Conductors with ground | 4 |
| Color Code | green/yellow, brown, black, gray |
| Jacket | Black PUR (RAL 9005) |
| Outer Ø ±10% (in) | 0.461 |
| Outer Ø ±10% (mm) | 11.70 |
| Voltage | 500 |
| min breaking load of suspension unit N | 1690 |
| tensile strength max. N | 240 |
| Cable Weight (≈lbs/mft) | 161 |
| Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 5 |
| Insulation | special polymer |
| Color Code | up to 5 conductors: HD 308 (VDE 0293-308): see part number |
| Stranding | specially adjusted layering around central suspension unit |
| Jacket Material | PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
| Jacket color | black (RAL 9005) |
| Peak operating voltage | 7179001: max. 500 V (DMX-bus) |
| Nominal voltage | Uo/U 300/500 V (supply conductors) |
| Current carrying capacity | |
| Testing voltage | conductor/conductor: 2000 V |
| Minimum bending radius | for laying and installation (fixed installation): |
| Tensile strength | with reference to VDE 0298-3 section 7.1 |
| Temperature Range | DIN VDE: |
| Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
| Burning Characteristics | Fire Performance: |
| Oil resistance | very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
| Chemical resistance | good - against acids, akalines, solvents, hydraulic liquids, etc. |
| Sunlight resistance | very good - enhanced due to black jacket color |
| Mechanical characteristics | the main mechanical characteristics accomplished by the PUR outer jacket are: » high tensile strength » high tear strength » high abrasion resistance » high notch resistance |
| For flexible application | very good |
| Application in track | not recommended |
| Approvals | CE, RoHS, PFAS-Free |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Part notes:
Please mention the required winding length when placing the order.
2 conductor cable does not have ground.
Other dimensions and colors are available on request.