Hybrid Cables

High-Voltage Cables for E-Vehicles & Testing

HV Robot

High-Voltage Cables for E-Vehicles & Testing

SERIES #: 3914

Highly flexible SABIX® insulated and PUR jacketed high-voltage single conductor cable with overall copper shield, suitable for cable tracks and robots - 3000 V, +125°C

Download PDF
HV Robot- SAB Specialty Cables

Marking for HV Robot 39142507:
SAB BRÖCKSKES · D-VIERSEN · HV Robot Uo/U 1.8/3 kV 95.0mm² cURus AWM Style 12150 AWM I/II A/B 80°C 2000V FT1 FT2

cURus
RoHS
PFAS-Free

Application

The HV Robot cable was specially developed for use in high-voltage testing under dynamic conditions. In automated test environments where cables are constantly moving or guided through drag chains, high mechanical resilience is just as important as electrical safety.

Outstanding Features

» Extremely flexible
» cURus recognized
» Good EMC characteristics
» Halogen-free
» Flexible at low temperatures
» Heat resistant
» Flame retardant and self-extinguishing
» Weather resistant
» High protection against environmental influences
» Extremely high mechanical resistance
» 100% oil resistance acc. to standard
» Suitable for cable tracks and robots
» Free from paint wetting impairment substances (PWIS-free)
» PFAS free

Construction

Conductor

bare copper strands acc. to IEC 60228, VDE 0295, class 6

Insulation

SABIX®

Stranding

non-woven tape

Shielding

tinned copper braiding

Wrappingnon-woven tape
Jacket MaterialPUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
Jacket colororange (RAL 2003)
Shaperound

Technical Specifications

Nominal voltage

Uo/U 1.8/3.0 kV AC
Uo/U 2.7/5.4 kV DC

Voltage

cURus: 2000 V

Current carrying capacity

acc. to VDE 0298-4

Testing voltage

6500 V

Minimum bending radius

fixed installation: 3 x O.D.
flexible application: 6 x O.D.

Temperature Range

cURus: up to +80°C    

DIN VDE: 
static: -50/+90°C
flexing:-40/+90°C
short-term use: +100°C (10000h); +125°C (2000h)

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Burning Characteristics

Fire Peformance:  
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
cURus FT1, FT2

Oil resistance

very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2

MUD resistancevery good - acc. to IEC 60992-360, IEC 61892-4, NEK TS 606
Chemical resistance

good - against acids, akalines, solvents, hydraulic liquids, etc.

Weather resistancevery good acc. HD 605
Ozone resistancevery good acc. to DIN EN 50396
Salt water resistancevery good acc. to UL 1309
Mechanical characteristics

the main mechanical characteristics accomplished by the PUR outer jacket are:
» high tensile strength
» high tear strength
» high abrasion resistance
» high notch resistance
» high transverse strength

For torsional movementvery good
For continuous flexingvery good
Application in trackrecommended
Approvals

cURus AWM, RoHS

Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part Numbers

Part notes:

Other dimensions and colors are available on request.

U.S. Headquarters