Hybrid Cables

High-Voltage Cables for E-Vehicles & Testing

HV Measuring Cable (DC)

High-Voltage Cables for E-Vehicles & Testing

SERIES #: 3839

High-voltage multi-conductor shielded PUR cable with colored conductors for scoop-proof - voltage measurement for use in test benches and test vehicles - 1800V DC, +125°C

Download PDF
HV Measuring Cable (DC)- SAB Specialty Cable

Marking for HV measuring cable DC 38339800:
SAB BRÖCKSKES · D-VIERSEN · ☇ HV-Messleitung (2 x 0.25 mm²) ☇  CE

CE
RoHS

Application

The HV Measuring Cable (DC) series is designed for precise, safe performance in demanding e-mobility environments. This high-voltage, multi-conductor shielded PUR cable features colored conductors and provides scoop-proof testing up to 1000 V DC / 5000 V AC, supporting reliable measurement under extreme conditions. Rated for continuous use up to +125°C, its robust PUR jacket ensures long service life with excellent resistance to oil, UV, and harsh mechanical stress. Certified to CE and RoHS standards, the HV Measuring Cable (DC) is purpose-built for test benches and test vehicles in the development of electric mobility systems. Typical applications include HV power electronics, batteries, inverters, and electric motors, where dependable voltage measurement and safety are critical.

Outstanding Features

» Temperature resistance up to +150°C (up to 3000 hours)
» High flexibility
» High abrasion resistance
» Easy harnessing

Construction

Conductor
tinned copper strands, extra fine wires
Insulation
FEP
Color Code
black, red
Stranding
in layers with tinned copper drain wire, 24 AWG
Shielding

double shield: alu. foil and tinned copper braiding

Inner JacketFEP, blue (RAL 5024)
Jacket MaterialPUR
Jacket colororange with black vertical stripes

Technical Specifications

Operating voltage
Uo 1000 V DC
U 1800 V DC
Contact Protection1000 V DC over the blue inner jacket; 5000 V AC over the blue inner jacket
Testing voltage

conductor/conductor: 5000 V AC
conductor/shielding: 5000 V AC

Minimum bending radius

fixed installation: 5 x O.D.
free movement: 10 x O.D.

Temperature Range

DIN VDE:
static: -50/+125°C
flexible: -40/+125°C
short-term use: +150°C (3000h)

Approvals
CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Additional Information

Possible on request:

» harnessed measuring cable with connected lab plugs to collect the tension at HV components.

Part Numbers

Part notes:

Other dimensions and colors are available on request.