Hybrid Cables

High-Voltage Cables for E-Vehicles & Testing

HV measuring cable (AC)

High-Voltage Cables for E-Vehicles & Testing

SERIES #: 3833

High-voltage multi-conductor shielded PUR cable with colored conductors for scoop-proof 1000V DC/5000 V AC voltage measurement for use in test benches and test vehicles - +125°C

Download PDF
HV Measuring Cable (AC)- SAB Specialty Cable

Marking for HV measuring cable (AC) 38339813:
SAB BRÖCKSKES D-VIERSEN · ↯HV-Messleitung (3 x 1.50 mm²) ↯ CE

CE
RoHS

Application

Engineered for durability, the HV measuring cable (AC) series is built to excel in demanding control environments. High-voltage multi-conductor shielded PUR cable with colored conductors for scoop-proof rated for 1000 V. DC/rated for 5000 V. AC voltage measurement for use in test benches and test vehicles - up to 125°C. It is built with a PUR jacket for durability and resistance in harsh conditions. With approvals such as CE, RoHS, it meets key international standards. This series also offers oil-resistant to perform in demanding environments. This makes it an excellent choice for reducing downtime and maximizing machine productivity.

Outstanding Features

» Temperature resistance up to +150°C (up to 3000 hours)
» High flexibility
» High abrasion resistance
» Easy harnessing

Construction

Conductor

tinned copper strands, extra fine wires

Insulation
FEP
Color Code
brown, black, gray
Stranding

in layers with tinned copper drain wire, 24 AWG

Shielding
alu. foil and tinned copper braiding
Inner JacketFEP, blue (RAL 5024)
Jacket MaterialPUR
Jacket colororange with black vertical stripes

Technical Specifications

Operating voltage

conductor/conductor: 1800 V DC
conductor/conductor: 1000 V AC

Testing voltage

scoop-proof testing:
1000 V DC over the blue inner jacket
5000 V AC over the blue inner jacket

conductor/conductor: 5000 V AC
conductor/shielding: 5000 V AC

Minimum bending radius
fixed installation: 5 x O.D.
free movement: 10 x O.D.
Temperature Range

DIN VDE:
static: -50/+125°C
flexible: -40/+125°C
short-term use: +150°C (3000h)

Temperature range conductorup to +180°C (short-term use: up to 205°C)
Oil resistance
very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
Approvals
CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Additional Information

Possible on request:
» harnessed measuring cable with connected lab plugs to collect the voltage at HV components.

Part Numbers