» Extremely high mechanical strength
» High protection against environmental influences
» 100% oil resistance acc. to standard
» Application range from -50°C to +125°C
HV 1000 C - SC - 4 AWG/1c - Flexible TPE-U high-voltage oil resistant single conductor cable with overall copper shield for for specialty, construction, and autonomous e-vehicles - 1000V AC/DC, +90°C, CE
Download PDF| Dimensions | 4 AWG/1c |
| mm2 | 25 |
| AWG | 4 |
| # of Conductors | 1 |
| Color Code | orange |
| Jacket | Orange TPE-U (RAL 2003) |
| Outer Ø (in) | 0.480 |
| Outer Ø (mm) | 12.20 |
| Voltage | 1000 |
| Ohmic resistance at 20°C max Ω/km | 0.78 |
| Cable Weight (≈lbs/mft) | 244 |
| Conductor | bare copper strands, extra fine wires |
| Insulation | TPFP |
| Color Code | orange |
| Shielding | double shield: alu. foil and tinned copper braiding |
| Jacket Material | TPE-U |
| Jacket color | orange (RAL 2003) |
| Nominal voltage | Uo/U max. 0.6/1 kV AC/DC |
| Testing voltage | conductor/shielding: 5000 V |
| Minimum bending radius | fixed installation: 5 x O.D. |
| Temperature Range | DIN VDE: |
| Low temperature resistance | -50°C acc. to DIN EN 60811-506 |
| Burning Characteristics | Fire Performance: |
| Oil resistance | very good - TMPU acc. to EN50363-10-2 + VDE 0207-363-10-2 |
| MUD resistance | very good - acc. to IEC 60992-360, IEC 61892-4 NEK TS 606 |
| Sunlight resistance | acc. to HD 605 |
| Ozone resistance | acc. to EN 50396 |
| Salt water resistance | acc.to UL 1309 |
| Mechanical characteristics | the main mechanical characteristics accomplished by the TPE-U outer jacket are: » high tensile strength » high tear strength » high abrasion resistance » high notch resistance » high transverse strength |
| For flexible application | very good |
| Application in track | not recommended |
| Approvals | CE, RoHS |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Part notes:
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025