Hybrid Cables

High-Voltage Cables for E-Vehicles & Testing

B 110 C

High-Voltage Cables for E-Vehicles & Testing

SERIES #: 0110

Shielded high-voltage silicone copper rope with overall copper shield for use in test benches and test vehicles - 3000V, +180°C

Download PDF
B 110 C- SAB Specialty Cable

Marking for B 110 C 1109507:
SAB BRÖCKSKES · D-VIERSEN · B 110 C Uo/U 1.8/3 kV 95.0 mm²

cURus
RoHS
PFAS-Free

Application

The B 110 C series is engineered for high-voltage reliability in demanding test environments. This shielded silicone copper rope cable with an overall copper braid is rated for 3000 V and continuous operation up to +180°C. Its Besilen® EM9 jacket (EN 50363-2-1 / VDE 0207-363-2-1) ensures outstanding heat resistance, flexibility, and long service life, even under harsh industrial conditions. Certified to cURus and RoHS standards, the B 110 C is halogen-free, UV-resistant, and designed for safe, durable use in test benches and test vehicles. With its extremely flexible construction, it is especially suited for connecting converters and high-voltage components in the field of electric mobility testing.

Outstanding Features

» Halogen-free
» Good EMC characteristics
» Flexible at low temperatures
» Heat resistant
» Flame retardant and self-extinguishing
» Weather resistant
» Extremely flexible
» PFAS free

Construction

Conductor
tinned copper strands, extra fine wires
Insulation
Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1
Shieldingdouble shield: alu. foil and tinned copper braiding
Jacket MaterialBesilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1
Jacket colororange (similar RAL 2004)

Technical Specifications

Nominal voltage
Uo/U 1.8/3 kV AC
Uo/U 2.7/5.4 kV DC
Voltage

cURus: 3000 V

Current carrying capacity
Testing voltage
6500 V
Minimum bending radius

fixed installation: 3 x O.D.
free movement: 6 x O.D.

Temperature Range

cURus: up to +150°C

DIN VDE:
static: -40/+180°C
flexible: -25/+180°C
short-term use: +250°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Fire Performance:
flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + VDE 0482-332-1-2
cURus FT 1, FT2

CorrosivityIEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Weather resistancevery good
For flexible applicationvery good
Application in tracknot recommended
Approvals
cURus, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Additional Information

Possible on request:

» harnessed measuring cable with connected lab plugs to collect the voltage at HV components

Part Numbers

Part notes:

Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025