Hybrid Cables

Cranes and Conveyor Cables

MR 460

Crane and Conveyor Cables

SERIES #: 8460

PUR control cable with black numbered conductors with fiber-reinforced jacket for areas with high mechanical stress - 500V, +90°C

Download PDF
MR 460- SAB Specialty Cable
Marking for MR 460 34601207:
SAB BRÖCKSKES · D-VIERSEN · MR 460 12 x 0.75 mm² 34601207 CE
CE
RoHS
PFAS-Free

Application

Tailored for industrial use, the MR 460 series ensures long-lasting performance in control wiring projects. PUR control cable with black numbered conductors with fiber-reinforced jacket for areas with high mechanical stress - rated for 500 V, up to 90°C. It is built with a PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 jacket for durability and resistance in harsh conditions. With approvals such as CE, RoHS, it meets key international standards. This series also offers halogen-free, UV resistance, oil-resistant, chemical resistance to perform in demanding environments. The result is dependable connectivity that keeps machinery and automation running at peak performance.

Outstanding Features

» Halogen-free
» Reinforced outer jacket for high mechanical stress
» Abrasion & notch resistant
» Good flexibility also at low temperatures
» Weather resistant
» Oil resistant
» Good chemical resistance
» Sunlight resistant
» PFAS free

Construction

Conductor
bare copper strands acc. to IEC 60228, VDE 0295, class 6
Insulation
TPE
Color Code
black conductors with consecutive numbers acc. to EN 50334 + VDE 0293-334
from 3 conductors: green/yellow ground
Stranding
specially adjusted layering
Wrappingnon-woven tape
Supporting Screenhigh-tech yarn
Jacket MaterialPUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
Jacket colorblack (similar RAL 9005)

Technical Specifications

Nominal voltage
Uo/U 300/500 V
Testing voltage
conductor/conductor: 2000 V
Minimum bending radius
fixed installation: 5 x O.D.
flexible application: 10 x O.D.
Temperature Range
DIN VDE: static: -50/+90°C
DIN VDE: flexible: -40/+90°C
Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Oil resistance
very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
Chemical resistance
good - against acids, akalines, solvents, hydraulic liquids, etc.
UV resistancevery good - enhanced due to black jacket color
Mechanical characteristics
the main mechanical characteristics accomplished by the PUR outer jacket are:
» high tensile strength
» high tear strength
» high abrasion resistance
» high notch resistance
» high transverse strength
Approvals
CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part Numbers

Part notes:

2 conductor cable does not have ground.
Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025