GP 400 Sy- 2 AWG/7c + 18 AWG/6x3, 400 Hz, Ground supply cable- symmetrical
Download PDF| Dimensions | 2 AWG / 7c + 18 AWG 6x3 |
| AWG | 2 |
| # of Conductors with ground | 7 |
| Jacket | Orange PVC |
| Outer Ø (in) | 1.457 |
| Outer Ø (mm) | 37.00 |
| Voltage | 1000 |
| DC resistance at 20°C max Ω/km | 2 AWG: 0.554, 18 AWG: 19.5 |
| Voltage drop | 2 AWG: 1.108, 18 AWG: 39 |
| Cable Weight (≈lbs/mft) | 2100 |
| Conductor | bare copper strands, fine wires acc. to IEC 60228 class 5 |
| Insulation | SABIX® |
| Color Code | 34000452: |
| Stranding | 1.0 mm²: each four conductors twisted in layers, wrapped with non-woven tape elements and 50 mm² conductors twisted in layers, blue conductor in the center, wrapped with non-woven tape |
| Jacket Material | PUR |
| Jacket color | orange |
| Nominal voltage | 1.0 mm²: Uo/U 115/200 V; |
| Testing voltage | conductor/conductor: 4000 V AC 50 Hz |
| Minimum bending radius | fixed installation: 4 x O.D. |
| Temperature Range | DIN VDE: |
| Halogen-free | acc. to IEC 60754-1 |
| Burning Characteristics | Fire performance: |
| Oil resistance | very good - acc. to EN 50363-10-2 |
| Oil and fuel resistance | petrol, diesel, and kerosene (Jet A-1) |
| MUD resistance | very good - acc. to IEC 60092-360 |
| Weather resistance | very good - acc. to HD 605 (VDE 0276-605) |
| Ozone resistance | very good - acc. to EN 50396 |
| Salt water resistance | very good - acc. to UL 1309 |
| Mechanical characteristics | the main mechanical characteristics accomplished by the outer jacket are: |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Part notes:
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025