GP 400 Sy - PUR - 7 x 35 mm² + 6 x 4 x 1.0 mm²

Part #: 34000452
CE
RoHS
PFAS-Free

Outstanding Features

» Price optimized
» Low capacity insulation
Questions?

GP 400 Sy

Part #: 34000452

GP 400 Sy - PUR - 7 x 35 mm² + 6 x 4 x 1.0 mm² - 400 Hz Ground Power supply cable - symmetrical for fixed installations- 1000V, +90°C, CE

Download PDF

Cable Configuration

Dimensions7 x 35 mm² + 6 x 4 x 1.0 mm²
# of Conductors30
Color Code
1.0 mm²: black numbered conductors: 1 - 24
35 mm² or 50 mm²: blue, 2 x white, 2 x brown, 2 x black
JacketOrange PUR
Outer Ø (in)min. 1.575 - max. 1.650
Outer Ø (mm)min. 40 - max. 41.9
Voltage1000
Ohmic resistance at 20°C max Ω/km35 mm²: 0.554 | 1.0 mm²: 19.5
Cable Weight (≈lbs/mft)2163

Construction

Conductor

bare copper strands, fine wires acc. to IEC 60228 class 5

Insulation
SABIX®
Color Code

34000452:
1.0 mm²: black numbered conductors: 1 - 24
35 mm²: blue, 2 x white, 2 x brown, 2 x black

34000453:
1.0 mm²: black numbered conductors: 1 - 24
50 mm²: blue, black numbered conductors

Stranding

1.0 mm²: each four conductors twisted in layers, wrapped with non-woven tape elements and 50 mm² conductors twisted in layers, blue conductor in the center, wrapped with non-woven tape

Jacket MaterialPUR
Jacket colororange

Technical Specifications

Nominal voltage

1.0 mm²:  Uo/U 115/200 V; 
50 mm²:  Uo/U max. 0.6/1 kV

Testing voltage

conductor/conductor: 4000 V AC 50 Hz

Minimum bending radius

fixed installation: 4 x O.D.
free movement: 6 x O.D.
for one single bend: 3 x O.D.

Temperature Range

DIN VDE:
static: -50/+90°C; 
flexible: -40/+90°C;
short-term use: +110°C (7500 h)

Halogen-free

acc. to IEC 60754-1

Burning Characteristics

Fire performance:
jacket material: UL 94 V2

Oil resistance

very good - acc. to EN 50363-10-2

Oil and fuel resistancepetrol, diesel, and kerosene (Jet A-1)
MUD resistancevery good - acc. to IEC 60092-360
Weather resistancevery good - acc. to HD 605 (VDE 0276-605)
Ozone resistancevery good - acc. to EN 50396
Salt water resistancevery good - acc. to UL 1309
Mechanical characteristics

the main mechanical characteristics accomplished by the outer jacket are:
» high tensile strength
» high tear strength
» high abrasion resistance
» high notch resistance
» high shear strength

ApprovalsCE, RoHS, PFAS-Free
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union