GP 400 SC- 2 AWG/1c + 18 AWG/4, 400 Hz, Ground supply cable-SingleCore
Download PDF| Dimensions | 2 AWG / 1c + 18 AWG/ 4c |
| AWG | 2 |
| # of Conductors with ground | 5 |
| Jacket | Orange PUR |
| Outer Ø (in) | 0.614 |
| Outer Ø (mm) | 15.60 |
| DC resistance at 20°C max Ω/km | 2 AWG: 0.393; 18 AWG: 20 |
| Voltage drop | 2 AWG: 0.786; 18 AWG: 40 |
| Cable Weight (≈lbs/mft) | 394 |
| Conductor | tinned copper strands, fine wires |
| Insulation | SABIX® |
| Color Code | control conductors: red, black, green, yellow power supply conductor: red |
| Stranding | control conductors within the power supply core |
| Inner Jacket | PUR, red |
| Jacket Material | abrasion resistant PUR |
| Jacket color | yellow |
| Max. permissible operating voltage | Uo/U 0.6/1 kV |
| Nominal voltage | Uo/U 115/200 V |
| Testing voltage | conductor/conductor: 4000 V AC 50 Hz |
| Minimum bending radius | fixed installation: 4 x O.D |
| Temperature Range | DIN VDE: |
| Halogen-free | acc. to IEC 60754-1 |
| Burning Characteristics | Fire performance: |
| Oil resistance | very good - acc. to EN 50363-10-2 |
| Oil and fuel resistance | petrol, diesel, and kerosene (Jet A-1) |
| MUD resistance | very good - acc. to IEC 60092-360 |
| Chemical resistance | good - against acids, akalines, solvents, hydraulic liquids, etc. |
| Weather resistance | very good - acc. to HD 605 (VDE 0276-605) |
| Ozone resistance | very good - acc. to EN 50396 |
| Salt water resistance | very good - acc. to UL 1309 |
| Mechanical characteristics | the main mechanical characteristics accomplished by the outer jacket are: |
| For flexible application | very good |
| Application in track | not recommended |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Part notes:
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025