» Low smoke halogen-free (LSHF)
» No flame propagation
» Good EMC characteristics
» Flame retardant and self-extinguishing
» Fulfills fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-2
» Fulfills fire protection requirements acc. to NFPA 130 section 8.6.7.1.1.1 and section 12.2.1 (1)[* NFPA 130 / FT4 only up to outer-ø¸ < 13 mm (0.512")]
» Flame retardant acc. to UN/ECE R118
» Tested acc. to American ASTM standard
» Good transmission rates and crosstalk attenuation
» PFAS free
SABIX® R 645 FRNC TP - 26 AWG/16pr - shielded, low smoke, halogen-free (LSHF) SABIX® data cable with colored twisted pairs and overall tinned copper shield with improved fire performance for railway applications acc. to EN 45545-2 - 300V, +90°C, CE
Download PDF| Dimensions | 26 AWG (≈18/38)/16pr |
| mm2 | 0.14 |
| AWG | 26 |
| # of Pairs | 16 |
| Color Code | #1- white/brown, #2- green/yellow, #3- gray/pink, #4- blue/red, #5- black/violet, #6- gray-pink/red-blue, #7- white-green/brown-green, #8- white-yellow/yellow-brown, #9- white-gray/gray-brown, #10- white-pink/pink-brown, #11- white-blue/brown-blue, #12- white-red/brown-red, #13- white-black/brown-black, #14- gray-green/yellow-gray, #15- pink-green/yellow-pink, #16- green-blue/yellow-blue |
| Jacket | Grayish Tan SABIX FRNC (RAL 7032) |
| Outer Ø ±10% (in) | 0.413 |
| Outer Ø ±10% (mm) | 10.50 |
| Voltage | 350 |
| Cable Weight (≈lbs/mft) | 99 |
| Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 5 |
| Insulation | special SABIX® |
| Color Code | DIN 47100: see part number |
| Stranding | pairwise, pairs in layers |
| Wrapping | foil |
| Shielding | tinned copper braiding |
| Jacket Material | special SABIX® |
| Jacket color | grayish tan (RAL 7032) |
| Peak operating voltage | 26 AWG: max. 350 V |
| Testing voltage | conductor/conductor: 1500 V |
| Minimum bending radius | fixed installation: 5 x O.D. |
| Temperature Range | DIN VDE: |
| Halogen-free | acc. to EN 50306-1 + EN 50264-1 Development of HCl is < 0.5% acc. to IEC 60754-1 pH-value is > 4.3 acc. to IEC 60754-2 Conductivity is < 10.0 μS/mm acc. to IEC 60754-2 Fluoric content < 0.1% acc. to IEC 60684-2 |
| Burning Characteristics | Flame Propagation: |
| Smoke Density | acc. to IEC 61034 + VDE 0482-1034 + ASTM E 662-09 |
| Toxicity | acc. to EN 50305+ VDE 0260-305 |
| For flexible application | good |
| Application in track | not recommended |
| Approvals | EN 45545, NFPA 130, UN/ECE/R118, CE, RoHS, PFAS-Free |
| Absence of harmful substance (RoHS) | acc. to RoHS directive of the European Union |
Part notes:
* NFPA 130 / FT4 only up to outer-ø < 13 mm (0.512”).
Other dimensions and colors are available on request.
U.S. Headquarters
SAB North America
344 Kaplan Drive, Fairfield, NJ 07004
SAB North America © 2025