SABIX R 645 FRNC TP - 20 AWG/6pr

Part #: 66450650
EN 45545
NFPA 130
UN/ECE/R118
CE
RoHS
PFAS-Free

Outstanding Features

» Low smoke halogen-free (LSHF)
» No flame propagation
» Good EMC characteristics
» Flame retardant and self-extinguishing
» Fulfills fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-2
» Fulfills fire protection requirements acc. to NFPA 130 section 8.6.7.1.1.1 and section 12.2.1 (1)[* NFPA 130 / FT4 only up to outer-ø¸ < 13 mm (0.512")]
» Flame retardant acc. to UN/ECE R118
» Tested acc. to American ASTM standard
» Good transmission rates and crosstalk attenuation
» PFAS free

Questions?

SABIX® R 645 FRNC TP

Part #: 66450650

SABIX® R 645 FRNC TP - 20 AWG/6pr - shielded, low smoke, halogen-free (LSHF) SABIX® data cable with colored twisted pairs and overall tinned copper shield with improved fire performance for railway applications acc. to EN 45545-2 - 300V, +90°C, CE

Download PDF

Cable Configuration

Dimensions20 AWG (≈16/32)/6pr
mm20.5
AWG20
# of Pairs6
Color Code
#1- white/brown, #2- green/yellow, #3- gray/pink, #4- blue/red, #5- black/violet, #6- gray-pink/red-blue
JacketGrayish Tan SABIX FRNC (RAL 7032)
Outer Ø ±10% (in)0.409
Outer Ø ±10% (mm)10.40
Voltage500
Cable Weight (≈lbs/mft)104

Construction

Conductor
bare copper strands acc. to IEC 60228, VDE 0295, class 5
Insulation
special SABIX®
Color Code

DIN 47100: see part number

Stranding
pairwise, pairs in layers
Wrappingfoil
Shieldingtinned copper braiding
Jacket Materialspecial SABIX®
Jacket colorgrayish tan (RAL 7032)

Technical Specifications

Peak operating voltage

26 AWG: max. 350 V
24 - 19 AWG: max. 500 V

Testing voltage

conductor/conductor: 1500 V
conductor/shielding: 1200 V

Minimum bending radius

fixed installation: 5 x O.D.
free movement: 10 x O.D.

Temperature Range

DIN VDE:
static: -40/+90°C
flexible: -30/+90°C

Halogen-free
acc. to EN 50306-1 + EN 50264-1
Development of HCl is < 0.5% acc. to IEC 60754-1
pH-value is > 4.3 acc. to IEC 60754-2
Conductivity is < 10.0 μS/mm acc. to IEC 60754-2
Fluoric content < 0.1% acc. to IEC 60684-2
Burning Characteristics

Flame Propagation:
no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 and EN 50305 + VDE 0260-305 section 9.1.2

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
flame retardant acc. to UL 1685 section 12, FT4/IEEE 1202
flame retardant acc. to ISO 6722 (UN/ECE R118)

Burning Tests:
acc. to ASTM E 162-09

Smoke Densityacc. to IEC 61034 + VDE 0482-1034 + ASTM E 662-09
Toxicityacc. to EN 50305+ VDE 0260-305
For flexible applicationgood
Application in tracknot recommended
ApprovalsEN 45545, NFPA 130, UN/ECE/R118, CE, RoHS, PFAS-Free
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part notes:

* NFPA 130 / FT4 only up to outer-ø < 13 mm (0.512”).
Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025