SABIX BL 443 C FRNC TT - 24 AWG/7tr

Part #: 64430725
DNV
CE
RoHS
PFAS-Free

Outstanding Features

» Low smoke halogen-free (LSHF)
» Asbestos-free
» Good EMC characteristics
» No flame propagation
» Flame retardant and self-extinguishing
» Flexible
» DNV
» For applications acc. to Hong Kong Convention
» PFAS free
Questions?

SABIX® BL 443 C FRNC TT

Part #: 64430725

SABIX® BL 443 C FRNC TT - 24 AWG/7tr - shielded, flexible, low smoke, halogen-free (LSHF) SABIX® data cable with colored twisted triads and overall copper shield with improved fire performance for marine applications - 300V, +90°C, DNV, CE

Download PDF

Cable Configuration

Dimensions24 AWG (≈14/34)/7tr
mm20.25
AWG24
# of Triads7
Color Code
#1- white/brown/green, #2- yellow/gray/pink, #3- blue/red/black, #4- violet/gray-pink/red-blue, #5- white-green/brown-green/white-yellow, #6- yellow-brown/white-gray/gray-brown, #7- white-pink/pink-brown/white-blue
JacketPigeon Blue SABIX FRNC (RAL 5014)
Outer Ø ±10% (in)0.417
Outer Ø ±10% (mm)10.60
Voltage300
Cable Weight (≈lbs/mft)108

Construction

Conductor
tinned copper strands acc. to IEC 60228, VDE 0295, class 5
Insulation
special SABIX®
Color Code

24 AWG: DIN 47100: see part number
22 - 19 AWG: white, blue with printed pair number

Stranding
conductors white, blue, red twisted to triads, triads twisted in layers
Wrappingfoil
Shieldingtinned copper braiding
Jacket Materialspecial SABIX® SHF 1 compound acc. to IEC 60092-360
Jacket colorpigeon blue (RAL 5014)

Technical Specifications

Peak operating voltage
max. 300 V
Testing voltage

conductor/conductor: 1500 V
conductor/shielding: 1200 V

Minimum bending radius

fixed installation: 5 x O.D.
free movement: 10 x O.D.

Temperature Range

DIN VDE:
static: -40/+90°C
flexible: -30/+90°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Flame Propagation:
no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A.

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosivityin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Smoke Densityacc. to IEC 61034 + VDE 0482-1034
For flexible applicationvery good
Application in tracknot recommended
ApprovalsDNV, CE, RoHS, PFAS-Free
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part notes:

Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025