SABIX A 280 FRNC X - 20 AWG/3c

Part #: 62800305
EN 45545
CE
RoHS
PFAS-Free

Outstanding Features

» Low smoke halogen-free (LSHF)
» No flame propagation
» Flame retardant and self-extinguishing
» Good ozone resistance
» Good oil and chemical resistance
» Fulfills fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3
» PFAS free
Questions?

SABIX® A 280 FRNC X

Part #: 62800305

SABIX® A 280 FRNC X - 20 AWG/3c - low smoke, halogen-free (LSHF) SABIX® cross linked wiring/control cable with white numbered conductors with improved fire performance for railway applications acc. to EN 45545-2 - 500V, +125°C, CE

Download PDF

Cable Configuration

Dimensions20 AWG (≈16/32)/3c
mm20.5
AWG20
# of Conductors3
Color Code
white numbered conductors
JacketBlack SABIX FRNC (RAL 9005)
Outer Ø ±10% (in)0.185
Outer Ø ±10% (mm)4.70
Voltage500
Ohmic resistance at 20°C max Ω/km40.1
Heating Value approx. kwh/Km115
Cable Weight (≈lbs/mft)24

Construction

Conductor
tinned copper strands, acc. to IEC 60228, VDE 0295, class 5
Insulation
special SABIX®
Color Code

white conductors with consecutive numbers acc. to EN 50334 + VDE 0293-334

Stranding

multi-conductor: in layers

Jacket Materialspecial SABIX®
Jacket colorsingle conductor: white (similar RAL 9010); multi-conductor: black (RAL 9005)
Shaperound

Technical Specifications

Nominal voltage
Uo/U 300/500 V
Testing voltage

conductor/conductor: 2000 V

Minimum bending radius
5 x O.D.
Temperature Range

DIN VDE:
static: -40/+125°C (single conductor in conduit)
static: -50/+125°C (multi-conductor cable in conduit)

Halogen-free

acc. to EN 50306-1 + EN 50264-1 are fulfilled
Development of HCl is < 0.5% acc. to IEC 60754-1
pH-value is > 4.3 acc. to IEC 60754-2
Conductivity is < 10.0 μS/mm acc. to IEC 60754-2
Fluoric content < 0.1% acc. to IEC 60684-2

Burning Characteristics

Flame Propagation:
no flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 and EN 50305 + VDE 0260-305 section 9.1.2.

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Smoke Densityacc. to IEC 61034 + VDE 0482-1034
Toxicityacc. to EN 50305+ VDE 0260-305
For flexible applicationvery good
Application in tracknot recommended
ApprovalsEN 45545, CE, RoHS, PFAS-Free
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part notes:

Other dimensions and colors are available on request.

Cable Accessories

CG 100 Gray

CG 100 Gray

Polyamide Dome Cord Grips

CG 100 Black

CG 100 Black

Polyamide Dome Cord Grips

CG 300

CG 300

Nickel Plated Brass Cable Glands

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2026