CATLine CAT 7A BL - 24 AWG/4pr

Part #: 17474621
RU
ABS
CE
RoHS
PFAS-Free

Outstanding Features

» ABS Type Approval
» TR IEC 60092-370
» Low smoke halogen-free
» Asbestos-free
» Flame retardant and self-extinguishing
» No flame propagation
» UL recognized
» Suitable for EtherCAT and EtherNET/IP applications
» PFAS free
Questions?

CATLine CAT 7A BL

Part #: 17474621

CATLine CAT 7A BL - 24 AWG/4pr - flexible low smoke halogen-free (LSHF) industrial CAT 7A Ethernet cables with star-quad stranded conductors or twisted pairs for maritime use - 300V, +75°C, UL recognized, ABS

Download PDF

Cable Reel/Coil Shorts Available for Purchase

Price Breaks (For Entire Length)

1 - 39 feet$4.40/ft
40+ feet$3.96/ft
  • Free ground freight in US for orders over $100
  • Reel/coil as is no cuts
  • Cable may be on a reel or coiled

Select Available Reel/Coils

Cable Configuration

Dimensions24 AWG (7 strand)/4pr
mm20.25
AWG24
# of Pairs4
Color Code
white-blue/blue, white-orange-orange, white-green/green, white-brown-brown
JacketBlack Special SABIX
Outer Ø ±10% (in)0.350
Outer Ø ±10% (mm)8.90
Voltage90
Cable Weight (≈lbs/mft)57

Construction

Conductor
bare copper strands, fine wires
Insulation
special polymer
Color Code
white-blue/blue, white-orange/orange, white-green/green, white-brown/brown
Stranding
conductors twisted to pairs, pairs shielded with foil, pairs together
Shielding

tinned copper braiding

Jacket Materialspecial SABIX®
Jacket colorblack

Technical Specifications

Peak operating voltage
max. 90 V
Voltage

UR: 300 V

Testing voltage

conductor/conductor: 2000 V
conductor/shielding: 2000 V

Minimum bending radius

fixed installation: 5 x O.D.
free movement: 10 x O.D.

Temperature Range

UR: up to +75°C

DIN VDE:
static: -40/+70°C
flexible: -30/+70°C

Halogen-free
acc. to IEC 60754-1 + VDE 0482-754-1
Burning Characteristics

Flame Propagation:
no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A

Fire Performance:
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Burning Tests:
UL Horizontal flame Test FT2, UL AWM Style 21080

Smoke Densityacc. to IEC 61034 + VDE 0482-1034
Corrosiveness of conflagration gasesin compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
Characteristic impedance100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-9-2 / CAT 7A
For flexible applicationgood
Application in tracknot recommended
ApprovalsUR AWM, ABS, CE, RoHS, PFAS-Free
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part notes:

Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025