TA 867 CF - 16 AWG/10c

Part #: 38671015
RU
CRU
CE
RoHS

Outstanding Features

» Excellent resistance against chemicals and solvents
» Excellent temperature resistance and flexibility at low temperatures
» Excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics
» UL / cUL recognized
Questions?

TA 867 CF

Part #: 38671015

TA 867 CF - 16 AWG/10c - shielded, chemical and solvent resistant FEP connection cable with black numbered conductors and overall copper shield with extended temperature range - 600V, +80°C, UL and cUL recognized

Download PDF

Cable Configuration

Dimensions16 AWG/10c
mm21.5
AWG16
# of Conductors with ground10
Color Code
black numbered conductors including a green/yellow ground
JacketBlack FEP (RAL 9005)
Outer Ø ±10% (in)0.398
Outer Ø ±10% (mm)10.10
Voltage600
Cable Weight (≈lbs/mft)158

Construction

Conductor
tinned copper strands acc. to IEC 60228, VDE 0295, class 5
Insulation
FEP, 6Y11 acc. to VDE 0207-6
Color Code

up to 5 conductors: HD 308 (VDE 0293-308): see part number
from 6 conductors: black conductors with consecutive numbers acc. to EN 50334 + VDE 0293-334
from 3 conductors: green/yellow ground

Stranding
in layers
Wrappingfoil
Shieldingtinned copper braiding
Jacket MaterialFEP, 6YM1 acc. to VDE 0207-6
Jacket colorblack (RAL 9005)

Technical Specifications

Nominal voltage
Uo/U 300/500 V
Voltage

UR/cUR: 600 V

Testing voltage

conductor/conductor: 2000 V
conductor/shielding: 2000 V

Minimum bending radius
7.5 x O.D.
Radiation resistance
1 x 107 cJ/kg
Temperature Range

UR/cUR: up to +150°C

DIN VDE:
static: -90/+180°C
flexible: -55/+180°C

Burning Characteristics

Fire Performance:
flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + VDE 0482-332-1-2
UL FT1, FT2

Oil resistance
very good - acc. to UL standard 758, at 80°C after 80 days
Chemical resistance
very good - against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds
For flexible applicationgood
Application in tracknot recommended
ApprovalsUR AWM, cUR AWM, CE, RoHS
Absence of harmful substance (RoHS)acc. to RoHS directive of the European Union

Part notes:

2 conductor cable does not have ground.
Other dimensions and colors are available on request.

U.S. Headquarters

SAB North America

344 Kaplan Drive, Fairfield, NJ 07004

SAB North America © 2025